起订量:
225-392 冲击式采样器IMPACT Sampler
中级会员第10年
代理商上海会彬仪器有限公司(简称:会彬仪器,HBI)成立于2014年。
自成立以来 一直专注于气体检测领域,是船舶气体检测产品专业供应商。我们为您提供:气体检测管,测毒管,气体检测仪,测氧测爆仪,标准气体和气体传感器以及校准和维修服务。
Shanghai Huibin Instrument Co., Ltd. Since its establishment, it has been focusing on the field of gas detection, and is a professional supplier of ship gas detection products.We provide you with: Gas detector tube, Toxic gas tube, Gas detector, Oxygen & Combustible gas detector, Standard gas and Gas sensor as well as calibration and maintenance services.
气体检测管解决方案:
美国Honeywell(原RAE华瑞),日本GASTEC,日本KITAGAWA,德国Drager,北京劳保所,印度Uniphos & MSA KWIK-DRAW,美国SENSIDYNE。有超过200种不同的检测管可针对500种以上的气体和蒸气进行准确的测量。
气体检测仪解决方案:
德国德尔格Draeger,日本理研RIKEN KEIKI,英国GMI,美国Honeywell BW,美国mPower,英国Crowcon等。
标准气体解决方案:美国CALGAZ,美国GASCO,大连科瑞气体等标准和特种气体。
烟感&温感解决方案:英国SOLO
红外测温与热成像解决方案:
德国DIAS红外公司,便携式红外测温仪、在线红外测温仪、在线式红外扫描热像仪、便携式红外热像仪、在线式红外热像仪、黑体、单元和多元红外探测器。
本公司产品广泛应用于各种领域及场所
重工业,环保,石化,交通,船舶,市政,消防,高校,科研,公共安全等众多领域。
作为向船舶、实验室、工业中分析、检测方案的提供者,会彬以其品质优良、价格合理的仪器及专业产品,贴切的应用和周到的服务诠释着会彬的承诺。
我们希望——成为您信赖的合作伙伴。
我们坚持——不断创新、提供高质量的服务,带给客户完善的解决方案。
我们营造——安全健康的工作环境,提供成长与发展机会,让员工乐在工作、享受工作。
我们分享——公司的经营成果、并以绩效为基础,让每一个成员成为会彬的主人。
冲击式采样器IMPACT Sampler
环境空气取样和室内空气研究的理想选择
在10升/分钟情况下,可使用任何泵
紧凑型设计
更高的流量提供了更高的灵敏度
操作方便
快速媒体变化的可移动过滤盒
一次性准备使用前油冲击盘减少颗粒反弹不清洁或润滑
包括雨盖保护取样在室外使用
可选的快速安装支架固定采样器几乎任何地方
冲击式采样器IMPACT Sampler
采集PM10,PM2.5,或PM粗(10-2.5um)在10升/分钟。高流量提高了采样灵敏度使其成为理想的环境取样和室内空气的研究。影响的可拆卸过滤盒和一次性前油冲击盘使其快速和易于部署(不清洁或润滑)。影响是在SKC展开微粒采样器的采样头(DPS)系统。该建议使用IMPACT冲击样泵。
Performance Profile
Flow Rate | 10 L/min |
50% Cut-point | 2.5 μm or 10 μm (model dependent) |
Impaction Discs | Recommended impaction disc to reduce particle bounce: 37-mm disposable pre-oiled porous plastic disc |
Collection Filter | 47-mm filter (requires impaction substrate), select material based on application |
Impactor Material | Aluminum (inlet) with brass barbed fitting for 3/8-in ID tubing |
Dimensions | 2.6 dia. X 1.8 H x 3.8 L in (7 x 5 x 10 cm) |
Weight | 0.5 lb (0.23 kg) |
Cat. No. | Description+ |
225-394 | Calibration Adapter, for IMPACT Sampler Calibration Adapter, replacement, for use with IMPACT Sampler, also used with DPS System, ea | |
225-397 | Filter Holder Opener, IMPACT Sampler Filter Holder Opener, replacement, for IMPACT Sampler, also used with DPS System, 1 ea | |
225-396 | Filter Holder, IMPACT Sampler Filter Holder, replacement, for IMPACT Sampler, holds 47-mm collection filter, also used with DPS System, ea | |
770-805 | HAZ-SCANNER Nitrogen Dioxide Sensor Nitrogen dioxide sensor, for HAZ-SCANNER Measures 0 to 50 ppm EDC No. EDC GB ND-2000 | |
225-3911 | IMPACT Sampler, for PM Coarse Sampling at 10 L/min IMPACT Sampler, two-stage inertial impactor for 10 L/min ambient PM Coarse (PM10-2.5) sampling, includes filter cassette (holders), calibration adapter, rain cap and PM Coarse Ring (Cat. No. 225-3912); suitable for use with sampling pumps operating at 10 L/min | |
225-390 | IMPACT Sampler, for PM10 Sampling at 10 L/min IMPACT Sampler, single-stage inertial impactor (included in DPS System) for 10 L/min ambient PM10 eampling, includes filter cassette, calibration adapter, and rain cap; suitable for use with sampling pumps operating at 10 L/min | |
225-392 | IMPACT Sampler, for PM2.5 Sampling at 10 L/min IMPACT Sampler, single-stage inertial impactor (included in DPS System) for 10 L/min ambient PM2.5 Sampling, includes filter cassette (holder), calibration adapter, and rain cap; suitable for use with sampling pumps operating at 10 L/min | |
225-395 | Impaction Substrates, 37 mm, for IMPACT Sampler Impaction Substrates, replacement, 37-mm porous plastic support pads, pre-oiled, ready to use, disposable, for use with IMPACT Sampler, also used with DPS System, pk/25 | |
225-395A | Impaction Substrates, 37 mm, for IMPACT Sampler Impaction Substrates, replacement, 37-mm porous plastic support pads, pre-oiled, ready to use, disposable, for use with IMPACT Sampler, also used with DPS System, pk/50 | |
225-395B | Impaction Substrates, 37 mm, for IMPACT Sampler Impaction Substrates, replacement, 37-mm porous plastic support pads, pre-oiled, ready to use, disposable, for use with IMPACT Sampler, also used with DPS System, pk/10 | |
225-399 | Mounting Bracket, for IMPACT Sampler Mounting Bracket Replacement, for IMPACT Sampler, also used with DPS System, ea | |
225-3912 | PM Coarse Ring, for IMPACT PM10 Sampler PM Coarse Ring, for use with IMPACT PM10 Sampler, adapts IMPACT PM10 Sampler to an IMPACT Coarse, includes filter cassettes | |
225-398 | Rain Cap, IMPACT Sampler Rain Cap Replacement, for IMPACT Sampler, also used with DPS System, ea | |
P31988 | Replacement Impactor Exhaust O-Ring, for the IMPACT Sampler and DPS System Replacement Impactor Exhaust O-Ring, for the IMPACT Sampler and DPS System, ea | |
P31989 | Replacement Impactor Inlet O-Rings, for the IMPACT Sampler and DPS System Replacement Impactor Inlet O-Rings, for the IMPACT Sampler and DPS System, pk/3 | |
P54202 | Replacement Impactor Inlet, 10 μm, for IMPACT Sampler Replacement Impactor Inlet, 10 μm, for IMPACT Sampler, ea | |
P54204 | Replacement Impactor Inlet, for IMPACT Sampler and DPS System Replacement Impactor Inlet, 2.5 μm, for IMPACT Sampler and DPS System, ea |