起订量:
TC20全自动细胞计数仪
中级会员第15年
代理商上海艾研生物科技有限公司于2011年创建,是一家聚焦于为生命科学科研实验室提供产品与技术服务的高科技服务型企业;上海艾研生物专注于国内外的实验仪器设备,实验室耗材,生物试剂及生物信息学软件的引进和推广,为生命科学研究实验用户提供专业、可靠和便捷的服务。核心客户群涵盖全国的三甲医院、疾病预防控制中心、大学、中科院等领域。
本着推广
科研仪器、实验技术、提高实验工作效率的经营方针,本企业重点瞄准数十家国际、国内生命科学领域厂商,着急引荐先进靠谱的产品和技术方案。
以市场导向,不断拓宽合作渠道,以更好满足生物医学实验室检测、分子生物学研究、细胞学研究、技因组学以及蛋白组学研究等应用对仪器和技术服务的需要。
目前,本公司主营产品包括:伯乐bio-rad荧光定量PCR仪(cfx 96 touch,cfx 384 touch,cfx connect),梯度PCR仪(T100,S1000,C1000 touch),电穿孔仪(micro pulser,gene pulser xcell),细胞计数仪(TC20),电泳垂直转印系统(1658033),水平电泳(subcell)蛋白转印仪(turbo 1704150),凝胶成像仪(geldco go,chemidoc xrs+,chemidoc mp,chemidoc touch),数字PCR仪(QX200),糖分析柱(HPX-87C,HPX-87H,HPX-87P);
赛默飞Thermofisher荧光定量PCR仪(QuantStudio 3,QuantStudio 5,QuantStudio 6,QuantStudio 7 ,7500 fast,stepone plus),梯度PCR仪(2720,9700,miniamp,miniamp plus,SimpliAmp,veriti 96,veriti pro,ProFlex三槽), 细胞计数仪(countess 3,countess 3 FL荧光),核酸蛋白荧光计(qubit 4.0),超微量分光光度计(nanodrop one,nanodrop one C);
艾本德eppendorf小型迷你离心机(minispin,minispin plus),台式高速离心机(5418,5420,5424,5425,5427,5430,5804,5810型),低速台式离心机(5702,5702R),台式高速冷冻离心机(5418R,5424R,5425R,5427R,5430R,5804R,5810R,5920R),恒温混匀仪(thermomixer C),真空浓缩仪(Concentrator plus);
另外本公司还经营艾本德eppendorf,吉尔森gilson,普兰德brand,赛默飞thermofisher,赛多利斯百得,瑞宁rainin,瑞士socorex等诸多品牌手动移液器,电动移液器,瓶口分液器,数字滴定器,连续分液器等;
密理博millipore,赛多利斯sartorius,颇尔pall过滤器,过滤膜,超滤膜包等;
实验室耗材Axygen,QSP,GCS,瑞宁滤芯吸头,PCR八连管,PCR板,离心管,移液管,分液管等常规耗材
以上为我们的主营业务范围,有其他产品需要可以浏览公司网站www.aybio3517.com, 竭诚为广大分子生物学领域的老师服务是我们的宗旨!
TC20全自动细胞计数仪
TC20全自动细胞计数仪
The TC20 automated cell counter counts mammalian cells in one simple step using its innovative auto-focus technology and sophisticated cell counting algorithm to produce accurate cell counts in less than 30 seconds. Upon insertion of a counting slide, the TC20 cell counter rapidly provides a total cell count (with or without trypan blue staining) and assesses cell viability via trypan blue exclusion.
Key Features and Benefits
· Compatible with a broad range of cell sizes and types — counts cell lines, primary cells (from tissue or blood), and stem cells
· Innovative auto-focus technology — removes the variation associated with manual focusing and leads to precise cell counts in 30 seconds
· Cell size gates — user selects a population of interest in complex samples, such as primary cells, or lets the cell counting algorithm do all the work
· Cell viability — analyzes cells accuray using multifocal plane analysis
· Easy to archive and analyze — stores up to 100 counts in the onboard memory for access any time, or use the optional TC20 data analyzer software on your PC to further analyze exported cell images
Getting all the data you need about your cell cultures is fast and easy; the TC20 cell counter and disposable counting slides eliminate the need for tedious setup, cleaning, or maintenance. The TC20 cell counter is simple and intuitive to use
Get Accurate and Reproducible Results
The TC20 automated cell counter uses microscopy with auto-focus that analyzes multiple focal planes to identify the best plane. Without requiring any user input, the sophisticated cell counting algorithm uses the image acquired from the best focal plane to identify cells and exclude debris, thereby calculating the total cell count. The auto-focus leads to highly reproducible cell counts with reduced user-to-user variability compared to a hemocytometer and cell counters with manual focus. Using auto-focus instead of subjective manual focusing is especially important when assessing cell viability because an incorrectly selected focal plane will lead to inaccurate results.
Unlike cell counters based on electrical impedance (Coulter principle), the TC20 image-based analysis allows the user to view the cells in real time, providing visual proof that the TC20 cell counter has correctly identified cells.
The TC20 automated cell counter provides accuracy comparable to results obtained with a hemocytometer. It can count cells with a 6–50 μm cell diameter and within a broad concentration range of 5 x 104–1 x 107cells/ml, which eliminates the need to dilute cells, thus reducing errors associated with sample dilutions prior to counting.
The counter uses disposable counting slides with a patent-pending design that ensures even distribution of cells throughout the counting chamber, regardless of the user's pipetting style, leading to accurate and consistent cell counts.
For complex samples composed of multiple cell populations, such as primary cells, users can adjust the cell size gates to define the population of interest that will be counted. When counting multiple sample replicates, the TC20 cell counter can save the position of the cell size gates and apply them to subsequent counts.
Cell Viability
The TC20 cell counter uses multifocal plane analysis to assess cell viability. The conventional method of analyzing viability using a single focal plane can lead to inaccurate conclusions because light scattering and the alignment of cells at different heights in a counting chamber can change the appearance of cells — live cells may appear to be dead and vice versa. To determine if cells are viable, the TC20 counter analyzes each cell using images acquired from multiple focal planes during the focusing step.
Minimize Your Sample Preparation
The broad concentration range of the TC20 cell counter eliminates the need to dilute cells prior to counting, reducing the errors associated with sample dilutions that may be necessary when counting cells by other methods. The counting algorithm discriminates and counts individual cells within clusters of up to five cells, providing accurate counts without the need to extensively declump cells prior to loading.
Counting time, sec | 30 |
Cell concentration range, cells/ml | 5 x 104–1 x 107 |
Optimal cell concentration range, cells/ml | 1 x 105–5 x 106 |
Cell diameter range, µm | 6–50 |
Sample volume, µl | 10 |
Data storage, counts | 100 |
Data export | Via USB flash drive |
Printer connectivity | Yes |
Dilution calculator | Yes |
Image of cells available | Yes |
Dimensions (W x D x H), cm (in) | 19 x 15 x 25.4 (7.5 x 6 x 10) |
Weight without the external power supply, kg (lb) | 2.2 (4.8) |