LFT 3000 高效过滤器扫描检漏测试系统
高级会员第5年
生产厂家作为气溶胶测量技术的专家,Palas®将其在颗粒和过滤技术领域制定安全标准的长期专业知识带入了中国,将其技术集成在高精度和认证仪器中,可用于生产和表征空气中的颗粒。作为一家通过ISO 9001:2015质量管理体系认证的公司,Palas®的解决方案符合欧洲标准(EN)、美国国家职业安全卫生研究所标准(NIOSH)、以及中国GB2626口罩检测标准。在环保方面,Palas®同样遵守多项环境监测行业标准(EN 15267, HJ653等)。
Palas® brings its long-lasting expertise in the development of safe standards in the particle and filter technology to China. We deliver unparalleled technology in the market integrated in high-precision and certified devices for generating and characterizing particles. As an ISO 9001:2015 certified company, our solutions are compliant with European EN norms, The National Institute for Occupational Safety and Health (NIOSH) Standard and of course with the Chinese GB2626 Standard. In terms of environmental protection, Palas® also complies with a number of environmental monitoring industry standards (EN 15267, HJ653, etc.).
为了确保过滤器的质量,ISO 29463-1要求对效率在99.95%以上的HEPA/ULPA过滤器(ISO 35H/H13)进行以下测试:
• 局部效率符合ISO 29463-4
• 整体效率符合ISO 29463-5
LFT 3000将ISO标准的要求与简单的程序运作和快速的测试运行相结合。它由计算机控制,配有相应的软件来执行测试,并能简单快速地检验可能的泄漏点。
除局部过滤器效率外,整体效率也是测试报告的一部分。
标准和证书
国内和国外标准
ISO 29463-4 ISO 29463-5
工作原理
测试系统由以下部分组成:
– 带流量测量和原气采样的供气管道
– 水平过滤器支架(不同尺寸过滤器的适配器)
– 原气侧的气溶胶发生器和稀释装置
– 带采样和集成粒子计数器的扫描系统
– 控制和评估装置,包括Windows界面软件
首先,进气以规定的体积流量通过内置过滤器。
在此过程中,粒子计数器测量上游的粒子浓度和尺寸。LFT系统的一个优点是测试对象的测试参数是根据过滤器等级的规格和相关的体积流量自动计算出来的。
设置和顺序被储存起来,可以随时调用进行重复测量。