品牌
其他厂商性质
深圳市所在地
Keysight 是德科技 81960A 快速扫描紧凑型可调谐激光源
¥11Keysight 是德科技 Agilent 81950A 激光源
¥16Keysight 是德科技 Agilent 81630B 传感器
¥17Keysight 是德科技 Agilent 81634B 传感器
¥13Keysight 是德科技 Agilent 81635A 传感器
¥15Keysight 是德科技 Agilent 81623B 探头
¥10Keysight 是德科技 Agilent 81628B 光功率探头
¥12Keysight 是德科技 Agilent 81626B 光探头
¥14Keysight 是德科技 86142B 高性能光谱分析仪
¥17Keysight 是德科技 Agilent 81610A 模块
¥17Keysight 是德科技 Agilent N4150A 测试系统
¥16Keysight 是德科技 Agilent 8166B 测试系统
¥14IXIA XG12 12-slot模块箱
Ixia’s XG12 12-slot modular chassis is the test and measurement industry’s highest port density test system available for Ethernet. It is a flexible platform that delivers the most comprehensive solution for performance, functional, and conformance testing of network equipment and network applications. Operating in conjunction with Ixia’s industry-leading test applications and automation APIs, the XG12 chassis provides the foundation for high scale and performance, layer 1-7 test solutions.
The XG12 supports up to 384 ports of 10 Gigabit Ethernet (10GE), 192 1GE ports, 24 ports of 100GE Higher Speed Ethernet (HSE) CFP MSA ports, 48 ports of 40GE HSE QSFP+ ports, 24 Packet over SONET (POS) ports, or 24 Asynchronous Transfer Mode (ATM) ports.
The XG12 chassis has more total power and cooling compared to Ixia’s XM chassis series. The XG12 has a front-to-back airflow system to ensure that all of Ixia’s highest density load modules can operate efficiently. A true modular construction maximizes the XG12’s serviceability. Each major system component is self-contained and field replaceable. The fan, power supply, and processor components are designed to be readily installed and removed. All Ixia XM load modules are hot-swappable which ensures a highly flexible and multi-user testing environment. Both of Ixia’s load module form factors, the XM and Standard modules are supported in the XG12, providing a seamless integration with existing Ixia test systems.
Slots | 12 |
---|---|
Size |
|
Chassis Modules and Weights | Chassis Frame:
|
Chassis Power1Requirements | Three, single phase, 200-240VAC 50/60Hz power sources rated at 20 Amperes each, are required to supply the chassis. Maximum power consumption per line cord and power supply:
|
Power Cords | (3) Power cords are required to operate the XG12 chassis power supplies for normal operating conditions. Power Cord shipments:
|
Operating System | Windows 7, 32-bit version |
Processor Module | Field replaceable and removable processor card module with an In 2.26 GHz Core™ 2 Duo processor with 4 GB CPU memory, and 250 GB SATA hard drive |
Fan Module | Field replaceable chassis fan assembly that is easily installed and removed |
Power Supply Module | Field replaceable power supply module that is easily installed and removed |
Current Load Modules for XG12 Rackmount Chassis2 | XM Form Factor (XMFF) load modules: Xcellon-Lava® High Density 40/100GbE products:
K2 Higher Speed Ethernet product line:
Xcellon Ultra™ High Performance Application Test product line:
NGY High Density 10 Gigabit Ethernet product line:
Fibre Channel Load Module products:
ImpairNet Load Module products:
Voice Quality Module:
NGY NP High Density 10GbE Application Test product line:
High Density Gigabit Ethernet product line:
Standard Form Factor (SFF) Load Modules for XG12 chassis:* Gigabit Ethernet TX, TXS, STX and STXS products:
10 Gigabit Ethernet LSM products:
Application and Encryption Test product line:
10-Gigabit UNIPHY and MacSec products:
Packet over SONET and ATM products:
Power over Ethernet (IEEE802.3af):
*Note. Requires 944-0007 Adapter Card for XM Chassis installations |
Timing Sources | Internal clock, synchronized with another Ixia chassis, or with Ixia GPS AFD-1, AFD2 IRIG-B units, or TDM units for FUSION (IxN2X) and Anue™ (timing) setups |
Connectors | Chassis Processor module:
Chassis frame:
|
Switches, LEDs, and LCD Display |
|
Industry Certifications | The chassis’ safety approvals are UL and CE. These certifications are only valid when the unit is operating from as specified. See endnote 1 for more information. |
Temperature3 | Operating: 41° F to 104° F (5° C to 40° C) |
Humidity | Operating: 0% to 85%, non-condensing |
Noise | The XG12 chassis running at maximum fan speed capacity may produce noise levels up to 86.5 dB(A). This is measured per the GR-63-CORE, Issue 1, and paragraph 5.6.3 specification. The use of appropriate ear protection is recommended to protect against hearing impairment. Consult local health and safety regulations for recommended maximum exposure levels for noise and ear protection devices. |
The XG12 supports a wide array of Ixia test applications, including:
940-0005
XG12 Chassis, a 12-slot XM form factor chassis, RoHS compliant, the chassis includes a modular CPU, fan module, power supply module, the Windows 7 Operating System, and IxExplorer software; REQUIRES selection of a free IxOS software version that is ordered separay. Please see Chassis Software versions that are available for the chassis.944-0007
Adapter Card, Supports Ixia standard form factor modules used with XG12 chassis (940-0005), XM12 chassis (941-0009), or the XM2 portable chassis (941-0002)
942-0002
AFD1, Auxiliary Function Device, GPS standalone unit for any Ixia chassis, RoHS compliant; Includes window mount antenna and 10 ft. cable, 6 ft. USB cable, 6 ft. serial cable, 6 ft. chassis sync cable and power supply; Configure by USB or serial cable; requires antenna to be installed with line-of-sight to the GPS salites; Operates with optional roof mount antenna kits available to improve reception, see 942-0003 GPS Antenna, Roof Mount kit with 200 ft. RG-58 cable.942-0003
GPS Antenna, Roof Mount Installation Kit; Includes roof mount TNC Bullet antenna, 200 ft. RG-58 cable and mast; operates with 942-0002 AFD1.942-0023
AFD2, Auxiliary Function Device, IRIG-B standalone timing unit for any Ixia chassis, RoHS compliant; Includes two 20 ft. RG-58 cables, 6 ft. USB cable, 6 ft. serial cable, 6 ft. chassis sync cable and power supply; Configure by USB or serial cable; requires cable to be connected to BITS or other timing source.942-0030
IxN2X Timing Distribution Module, standalone unit for Ixia XM2 (941-0003) and XM12 (941-0009) chassis to connect and synchronize up to eight (8) XM chassis to one or a stack of IxN2X chassis: IxN2X 2-slot portable (971-0100), IxN2X 4-slot chassis (971-0101), RoHS compliant; Includes one RJ-11 to dual-RJ-11 cable, USB cable, power supply, and one IxN2X rack-to-rack chassis synchronization cable, 3 meter length (971-0104).942-0050
Ixia Timing Distribution Module, standalone unit for Ixia XM and XG chassis series to connect and synchronize up to eight (8) chassis to one Anue 3500 chassis or any other device providing 10MHz sync signal. RoHS compliant; Includes one RJ-11 to dual-RJ-11 cable, USB cable, power supply, and one RG-58 Cable, SMA Male to BNC Male, 5ft (942-0051).
1 The North American power cord has a NEMA L6-20P plug that goes to the power source and an IEC-60320-C19 receptacle that plugs into the XG12 chassis. The power cord is rated to 16 Amperes. The plug and receptacle are rated for 20 Amperes. The XG12 chassis is UL certified when using the 200-240VAC power cords supplied with the chassis. For international shipments power cords are provided for the target country and are included with the purchase of the chassis.
2 For a complete list of all Ixia load modules supported by the XG12 chassis please refer to the Ixia Hardware and Reference guide document and the Product Compatibility Matrix that are available under the Support section of the www.ixiacom.com website.
3 Some high density / high performance load modules may require a lower ambient air operating temperature. If this is the case, the operating temperature will be lowered for the chassis to what is specified for the load module datasheet.
P/N: 915-0125-01 Rev C, December 2012
This material is for informational purposes only and subject to change without notice. It describes Ixia's present plans to develop and make available to its customers certain products, features and capabilities. Ixia is only obligated to provide those deliverables specifically included in a written agreement between Ixia and the customer.