伺服阀R900961252 4WS2EM10-4X/10B3T315K8DV-24停产,升级5X
时间:2024-12-30 阅读:58
伺服阀R900961252 4WS2EM10-4X/10B3T315K8DV-24停产,升级5X
R900961252 4WS2EM10-4X/10B3T315K8DV-24停产,升级5X
R900378570 4WS2EM10-4X/20B2ET315Z8DM由下述型号组合替代: 4WS2EM10-5X/20B11ET315K8DV+Z8
R900772317 4WS2EM10-5X/60B11T315K31CV-114
R900956598 4WS2EM10-51/75B11T315K31DV
R900956128 4WS2EM10-5X/10B11ET315K31EV
R900781091 4WS2EM10-52/30B11ET315K31BV
R900949285 4WS2EM10-51/30B11ET315K31EV
R900922801 4WS2EM10-5X/90B11ET315K31EV
R900243941 4WS2EM10-51/75B11ET315K31DV
R901020256 4WS2EM10-5X/60B11ET315K8DV
R901043430 4WS2EM10-5X/30B11ET315K8AV
R901237664 4WS2EM10-5X/90B11XNT210K31EV-102
R900571581 4WS2EM10-4X/60B2ET315K8EM-26
R900949286 4WS2EM10-5X/60B11ET315K31EV
R901020256 4WS2EM10-5X/60B11ET315K8DV
R900931560 4WS2EM16-2X/150B12ET315K8DM
R901020256 4WS2EM10-5X/60B11ET315K8DV
R900750593 4WS2EM10-5X/10B11ET315K8BV
R900938822 4WS2EB10-4X60B2ET70K8EV由下述型号组合替代,R901477083 4WS2EM10-5X/60B11ET210K8EV R900940091 HSZ10A345-3XN00
R901011692 4WS2EM10-5X/20B11XHET315K31EV
R901370776 4WS2EM10-5X/90B11XHET210K31EV-100
R901423633 4WS2EM6-2X/25B11ET210K17EV
R901116633 4WS2EM10-5X/5B11XHET315K31EV-100
R901537032 4WS2EM10-5X/90B11XDET315CEV-100
R901039619 4WS2EM10-5X/75B11XHT315K31EV
R901101469 4WS2EM10-5X/75B11T315K8CV104
R900971966 4WS2EM6-2X/10B11ET315K17DV
伺服阀故障及原因
1)阀不工作
原因有:马达线圈断线,脱焊;还有进油或进出油口接反。再有可能是前置级堵塞,使得阀芯正好卡在中间死区位置,阀芯卡在中间位置当然这种几率较少。马达线圈串联或并联两线圈接反了,两线圈形成的磁作用力正好抵消。
(2)阀有一固定输出,但已失控
原因:前置级喷嘴堵死,阀芯被赃物卡着及阀体变形引起阀芯卡死等,或内部保护滤器被赃物堵死。要更换滤芯,返厂清洗、修复。
(3)阀反应迟钝、响应变慢等
原因:有系统供油压力降低,保护滤器局部堵塞,某些阀调零机构松动,及马达另部件松动,或动圈阀的动圈跟控制阀芯间松动。系统中执行动力元件内漏过大,又是一个原因。此外油液太脏,阀分辨率变差,滞环增宽也是原因之一。
(4)系统出现频率较高的振动及噪声
原因:油液中混入空气量过大,油液过脏;系统增益调的过高,来自放大器方面的电源噪音,伺服阀线圈与阀外壳及地线绝缘不好,是通非通,颤振信号过大或与系统频率关系引起的谐振现象,再则相对低的系统而选了过高频率的伺服阀。
(5)阀输出忽正忽负,不能连续控制,成“开关”控制。
原因:伺服阀内反馈机构失效,或系统反馈断开,不然是出现某种正反馈现象。
(6)漏油
原因:安装座表面加工质量不好、密封不住。阀口密封圈质量问题,阀上堵头等处密封圈损坏。马达盖与阀体之间漏油的话,可能是弹簧管破裂、内部油管破裂等。
伺服阀故障排除,有的可自己排除,但许多故障要将阀送到生产厂,放到实验台上返修调试,再强调一遍:不要自己拆阀,那是很容易损坏伺服阀零部件的。