其他品牌 品牌
生产厂家厂商性质
太原市所在地
一满足标准Meet the criteria:
GB/T 1410-2006、ASTM D257-99、GB/T 10581-2006、GB/T 1692-2008、GB/T 2439-2001、GB/T 12703.4-2010 、GB/T 10064-2006、GB /1672-1988
二、仪器主要概述The main overview of the instrument:
1.体积表面电阻率测试仪又简称高阻计测试仪既可以测量高电阻又可以测量微电流。
1. Volumetric surface resistivity tester, also called high resistivity tester, can measure both high resistance and micro-current.
2.采用了德国大规模集成电路。
2. Using German LSI.
3.采用进口品牌电子元器件,使仪器测量精度高,质量更加有保证,操作简单,体积小,重量轻,触摸屏操作,主界面显示电压、电流、电阻、电阻率、厚度、极化时间。
3. Using imported brand electronic components, the instrument has high measurement accuracy, better quality assurance, simple operation, small size, light weight, touch screen operation, main interface display voltage, current, resistance, resistivity, thickness, polarization time.
4.测试模式切换可以切换固体、粉体、液体。
4. Test mode switching can switch solid, powder and liquid.
5.电阻测量量限从1×104Ω ~1×1018 Ω,电流测量量限从2×10-4 ~1×10-16A。
5. The measurement limits of resistance are 1*104_~1*1018_, and the measurement limits of current are 2*10-4~1*10-16A.
6.体积表面电阻率测试仪适用于橡胶、塑料、薄膜、及粉体、液体、及固体和膏体形状的各种绝缘材料体积和表面电阻值的测定。本仪器除能测电阻外,还能直接测量微弱电流。
6. The volume surface resistivity tester is suitable for measuring the volume and surface resistance of various insulating materials with rubber, plastic, film, powder, liquid, solid and paste shapes. In addition to measuring resistance, the instrument can also directly measure weak current.
三、主要特点Main characteristics:
1.显示方式:彩色触摸屏。
1. Display mode: color touch screen.
2.测量时间显示:准确确定试样极化时间,使测量结果更加准确。
2. The measurement time shows that the polarization time of the sample can be determined accurately to make the measurement result more accurate.
3.试验测试电压:0-1000V任意调节。
3. Test voltage: 0-1000V arbitrary adjustment.
4.10V、50V、100V、250V、500V、1000V自动调节。
4.10V, 50V, 100V, 250V, 500V, 1000V automatic regulation.
5.电阻测量量程为0.01×104Ω ~1×1018Ω
5. The measuring range of resistance is 0.01*104_~1*1018_.
6.电流测量量程为2×10-4A ~1×10-16A
6. Current measurement ranges from 2 x 10-4A to 1 x 10-16A
7.测试前无须人工手动去调节电流是否归零,GHT-G322A体积表面电阻率测试仪在实验前会自动校准电流归零。
7. There is no need to manually adjust the current to zero before testing. GHT-G322A Volume Surface Resistivity Tester will automatically calibrate the current to zero before testing.
8.测试开始后无须人工手动去调节电压档位,本仪器测试时候内部自动调节电压。
8. There is no need to manually adjust the voltage level after the start of the test. The instrument automatically adjusts the internal voltage during the test.
9.测试开始后无须人工手动调节次方档位,本仪器测试时候内部自动调节次方档位。
9. There is no need to manually adjust the secondary gear after the start of the test. The instrument automatically adjusts the secondary gear during the test.
10.所有测试电压0-1000V 测试时电阻结果直读,免去老式高阻计在不同测试电压下或不同量程时要乘以系数等使用不便的麻烦,使测量超高电阻就如用万用表测量普通电阻样简便。
10. Direct reading of resistance results for all test voltages of 0-1000V eliminates the inconvenience of multiplying coefficients for old high resistance meters under different test voltages or in different measuring ranges, which makes measuring super high resistance as simple as measuring ordinary resistance samples with multimeter.
11.既能测超高电阻又能测微电流。
11. It can measure both ultra-high resistance and micro-current.
12.环境温度0℃~40℃。
12. The ambient temperature ranges from 0 40 C.
13.相对湿度<80%。
13. Relative humidity < 80%.
14.中英文语言切换。
14. Language switching between Chinese and English.
15.测试结果对比分析。
15. Comparative analysis of test results.
16.USB通讯。
16. USB communication.
17.测试结果内部储存。
17. Test results are stored internally.
18.测试结果打印。
18. Print test results.
19.三组试样同时测试电极(选配)。
19. Three groups of samples were tested at the same time.
20.计算机控制软件(选配)。
20. Computer control software (optional).
21.质保3年。
21. Three-year warranty.
22.免费升级。
22. Free upgrade.
23.终生维护、维修。
23. Lifelong maintenance and repair.
四、技术指标Technical Indicators:
1、电阻测量范围: 0.01×104Ω ~1×1018Ω。
1. The range of resistance measurement is 0.01*104_~1*1018_.
2、电流测量范围: 2×10-4A~1×10-16A。
2. Current measurement range: 2 x 10-4A-1 x 10-16A.
3、显 示 方 式:彩色触摸屏
3. Display mode: color touch screen
4、内置测试电压:0-1000V自动调节(可根据要求调节到需要的电压)
4. Built-in test voltage: 0-1000V automatic regulation (can be adjusted to the required voltage according to requirements)
5、基本准确度:1% (*注)
5. Basic Accuracy: 1% (* Note)
6、使用环境: 温度:0℃~40℃,相对湿度<80%
6. Use environment: temperature: 0 40 C, relative humidity < 80%.
7、机内测试电压:0-1000V 任意调节,10V/50V/100V/250V/500V/1000V自动调节。
7. In-machine test voltage: 0-1000V arbitrary regulation, 10V/50V/100V/250V/500V/1000V automatic regulation.
8、供电形式: AC 220V,50HZ 体积表面电阻率测试仪详细说明
8. Power supply form: AC 220V, 50HZ 体积表面电阻率测试仪详细说明
产品图片Product picture::
橡胶树脂击穿电压试验仪
适用材料:
主要适用于固体绝缘材料如:塑料、薄膜、树脂、云母、陶瓷、玻璃、绝缘油、绝缘漆、纸板等介质在工频电压或直流电压下击穿强度和耐电压时间的测试;
电压击穿试验仪采用计算机控制,试验过程中可在线观察试验曲线;自动存储试验条件及试验结果等数据,并可存取、显示、打印.
橡胶树脂击穿电压试验仪计算机系统及软件包:
1、试验软件是我公司新研发的功能强大、操作简单、显示直观的试验软件系统。
2、采用计算机控制通过人机对话方式,完成对绝缘介质工频电压击穿,工频耐压试验。
3、试验过程中可动态绘制出试验曲线,试验的曲线可以多种颜色叠加对比,局部放大,曲线上任意一段可进行区域放大分析;
4、可对试验数据进行编辑修改,灵活适用;
试验条件及测试结果等数据可自动存储;
6、试验报告格式灵活可变,适用于不同用户的不同需求;
7、可对一组试验中曲线数据的有效与否进行人为选定;
8、试验结果数据可导入EXECL,WORD文档编辑;
9、软件设备人员管理功能,试验人员可设置自己的试验项目和试验参数,设置自己的试验内容后别人无法进入程序;
10、过电流保护装置有足够的灵敏度,能够保证试样击穿时在0.1S内切断电源;
11、仪器运行的持久性: 仪器可连续运行使用,不需为保护仪器而定期停机。
技术参数:
1、输入电压:AC220V 50Hz
2、输出电压:AC:0~50kV; DC:0~60kV
3、输出功率: 3kVA
4、测量范围: AC:0~50kV; DC:0~60kV
5、升压速率: 0. 1kV/s、0.2KV/S、0.3KV/S、0.5KV/S、1KV/S、2KV/S、3kV/s
6、耐压时间: 0~4H
7、试验方式:
直流试验:1、匀速升压 2、梯度升压 3、耐压试验
交流试验:1、匀速升压 2、梯度升压 3、耐压试验
8、判停方式两种:1、电压判停 2、电流判停
9、电压电流采集方式:光电隔离采集,有效保证控制系统的安全性和可靠性。
10、试验介质:空气,试验油
11、安装灵敏度较高的过电流保护装置保证试样击穿时在0.05S内切断电源。
12、采用先进智能集成电路匀速调压。
13、支持短时间内短路试验要求。
14、电压试验精度: ≤ 1%。
15、试验电压连续可调: 0--50KV。
16、电流可采集到m*
17、漏电流 : 1~30 mA可由计算机软件自由进行设定
18、电 源 : 交流220V±10%的单相交流电压和50Hz±1%的频率
19、试验环境温度: 15 ~ 30℃,相对湿度:0~85%能够稳定运行。
20、外形尺寸长×宽×高:1000mm×700 mm×1300mm(参考)
21、设备自重: 150Kg(参考)
22、接地要求仪器需要单独接地,接地附合国家标准要求,金属棒深埋地下至少要1.5米以下
结构原理:
1、主要由:升压系统(高压变压器)、西门子PLC控制系统、电极、油箱、电极定位架、计算机数据处理系统、软件等组成;
2、计算机---西门子PLC控制系统---调压装置----升压变压器-----试样;
3、高压变压器主要产生试样所需的直流电压;
4、调压器用于调节升压变压器输入端电压以产生高压所需的输入电压;
5、电压测量主要是从高压变压器测量端测量,高压变压器测量端和高压端是线性的;
6、放电系统在试验做完以后自动放电,以免产生放电对人身的危害;
安全保护:
(1)门限位保护:不关门,即使通电点实验开始,设备无任何反应,软件有:安全门未关闭提示。
(2)电压归零保护:如果在实验过程中,突然断电,下次开机后,会自动回到零位,保证初始电压为在零位
(3)终止电压保护:可以通过软件设定终止电压,保证在升压过程中如果出现异常升到电压后,自动终止并归零
(4)高压机械限位:如果软件系统失去控制,电压继续往上升,到高压限位后自动归零如果在击穿后未判停,通过过流保护器采集数据保证电压自动归零有高压指示灯,通过观察指示灯的状态来判断实在升压还是在零位如果长时间做实验,为保证设备的良好运行,设备留有变压器排气口,保证变压器的良好运行,增长使用寿命如果在实验中,试样有异味或者出现燃烧和冒烟现象,可以通过排风系统进行排除。
(5)独立接地保护
(6)短路保护
(7)软件误操作保护
(8)漏电保护
(9)实验结束放电保护