ZC-90D高绝缘电阻测量仪基本性能
时间:2022-10-17 阅读:1044
ZC-90D高绝缘电阻测量仪基本性能:
1,准确度高(基本误差±1%),读数稳定(3 1/2位数字显示),抗干扰强
High accuracy (basic error ±1%), stable reading (3 1/2 digits), strong immunity from interference
2,设备符合国家标准GB/T3048.5规定要求
Equipment meets national standard GB/T 3048.5 requirements
3,防静电地坪工程,施工和验收
Anti-static floor engineering, construction and acceptance
4,用于煤矿输送带表面电阻测量
Measuring the surface resistance of coal conveyor belt
5,用于防静电材料产品生产、ZC-90D高绝缘电阻测量仪防静电器材,防静电鞋帽,手套,服装等测量和检验
For anti-static materials production, anti-static equipment, anti-static shoes and hats, gloves, clothing and other measurement
and inspection
测试电压 test voltage 10V 50V | 测试电压 test voltage 100V 500V | ||
测量范围Measuring range | 基本误差Intrinsic error | 测量范围Measuring range | 基本误差Intrinsic error |
0-10^8 | ±(1%RX+2字character) | 0-10^9 | ±(1%RX+2字character) |
>10^8—10^9 | ±(2%RX+2字character) | >10^9—10^10 | ±(2%RX+2字character) |
>10^9—10^11 | ±(3%RX+2字character) | >10^10—10^12 | ±(3%RX+2字character) |
>10^11—10^12 | ±(5%RX+3字character) | >10^12—10^13 | ±(5%RX+3字character) |
>10^12—10^13 | ±(10%RX+5字character) | >10^13—10^14 | ±(10%RX+5字character) |