环刚度试验机是在试验机上的一种改进,当环刚度试验机不能正常工作,总结了以下几点:

Ring stiffness testing machine is improved in the universal testingmachine, when not ring stiffness testing machine normal work, summed up the following:

1环刚度试验机主机电源不亮,不能上下移动

1 ring stiffness testing machine power does not light, not to move up and down

2.检查接入试验机的电源线路是否连接正常;

The power supply line 2 check access testing machine is connected properly;

3.检查急停开关是否处于拧起状态;

3 check the emergency stop switch is in a twisted state;

4.检查接入试验机的电源电压是否正常;

Supply voltage 4 check whether the normal access testing machine;

5.检查机器插座上的保险是否烧断,请取出备用保险丝安装即可。

5 check the socket on the insurance is burn out, remove the spare fusecan be installed.

6.环刚度试验机主机电源有电但设备不可以上下移动

6 ring stiffness testing machine power supply with power but the equipment can not move up and down

7.检查是否是15S(时间)以后设备还无法移动,因为主机开机需要自检,大概需要15S时间;

7 check whether the 15S (time) after the equipment also cannot be moved, because the host power needed to self, probably need 15S time;

8.检查上下限位是否再恰当的位置,有一定的运行空间;

8 check the upper and lower limit is again appropriate position, there isa certain space operation;

9.检查接入试验机的电源电压是否正常

Supply voltage 9 check whether the normal access testing machine

10.急停按钮是否被按下

10 emergency stop button is pressed

如果按上面几种还是不能处理问题,可厂家工程师予以解决。

If the above several still can not deal with the problem, can contact the factory engineer to solve.