sephadex G-25凝胶过滤填料

sephadex G-25凝胶过滤填料

参考价: 面议

具体成交价以合同协议为准
2022-03-29 15:46:17
554
属性:
供货周期:现货;应用领域:环保,化工,生物产业,制药;主要用途:利用分子筛作用,适合用有机溶剂分离嗜脂性分子,可以非常经济地大规模制备各种天然产;葡聚糖凝胶LH-20:100g,500g;葡聚糖凝胶LH-60:100g,500g;
>
产品属性
供货周期
现货
应用领域
环保,化工,生物产业,制药
主要用途
利用分子筛作用,适合用有机溶剂分离嗜脂性分子,可以非常经济地大规模制备各种天然产
葡聚糖凝胶LH-20
100g,500g
葡聚糖凝胶LH-60
100g,500g
关闭
北京瑞达恒辉科技发展有限公司

北京瑞达恒辉科技发展有限公司

免费会员3
收藏

组合推荐相似产品

产品简介

sephadex G系列填料,业内普遍认可的凝胶过滤填料。
美国GE/通用电气生命医疗部,其业务主要包括基因科学、蛋白质科学,药物开发和工业生产。从基因到药物, 促使个性化药物变成可能。
sephadex G-25凝胶过滤填料

详细介绍

 

Instructions for Sephadex Media

Sephadex is a beaded gel prepared by crosslinking dextran with epichlorohydrin. Its main application is group separations of low and high molecular weight molecules. Desalting is the most common use. Desalting with Sephadex is superior to dialysis because of the considerable time savings, the low dilution factor (which can be as low as 1.4:1), and the high activity recoveries even with very small amounts of sample. Sephadex G-25 is available prepacked in PD-10 columns, which are ideal for rapid, routine work.

Related applications include buffer exchange and the removal of small molecules during the preparation of large biomolecules, such as ampholytes, detergents, radioactive or fluorescent labels, and phenol (during DNA purification).

Table 1. Gel Characteristics

Gel Type

Fractionation Range, Globular Proteins (D)

Fractionation Range, Dextrans (D)

Approx. Bed Volume (mL swelled per g dry)

Approx. Dry Bead Diameter (µm)

Approx. Maximum Operating Pressure (bar)

G-10

≤700

≤700

2–3

40–120

*

G-15

≤1500

≤1500

2.5–3.5

40–120

*

G-25

Superfine Fine Medium Coarse

1000–5000

(all grades)

100–5000

(all grades)

4–6

(all grades)

20–50

20–80

50–150

100–300

*

G-50

Superfine Fine Medium Coarse

1500–30000

(all grades)

500–10000

(all grades)

9–11

(all grades)

20–50

20–80

50–150

100–300

*

G-75 G-75

Superfine

3000–80000

3000–70000

1000–50000

1000–50000

12–15

12–15

40–120

20–50

0.16

0.16

G-100 G-100

Superfine

4000–150000

4000–100000

1000–100000

1000–100000

15–20

15–20

40–120

20–50

0.096

0.096

G-150 ** G-150

Superfine

5000–300000

5000–150000

1000–150000

1000–150000

20–30

18–22

40–120

20–50

0.036

0.036

 

G-200 ** G-200

Superfine

5000–600000

5000–250000

1000–200000

1000–200000

30–40

20–25

40–120

20–50

0.016

0.016

 

* The beads behave as rigid spheres and therefore obey Darcy's Law: the flow rate is proportional to the pressure drop over the bed and inversely proportional to the bed height.

** Sephadex G150, G150SF, G200 & G200SF are discontinued products.

 

Swelling

Sephadex is supplied as a dry powder, and must be allowed to swell in excess buffer before use. Filter all buffers through a 0.22-µm filter to help prevent microbial growth.

1. Weigh out the appropriate amount of dry Sephadex for the required bed volume of your column (Table 1). If packing at the maximum pressure for the gel, choose the lowest bed volume factor (mL/g) for calculating the amount of dry Sephadex.

2. Add enough buffer to equal the total volume of the column plus 30%. Swelling times for the different types of Sephadex are given in Table 2. The process is accelerated by using a boiling water bath.

3. After swelling is complete, decant the supernatant.

 

4. Add buffer to make a 75% suspension.

5. Degas the suspension before packing.

Packing By Gravity Flow

1. Pour the entire slurry into the column in one portion, taking care not to trap air bubbles.

2. Start the gravity flow to initiate packing.

Packing Using a Flow Adaptor

Good packing is essential to obtain good resolution. Ideally, the column should be packed at the highest pressure possible without deforming the beads.

For Sephadex G-10–G-50, the beads behave as rigid spheres. The pressure tolerance of the column is the limiting factor: pack at the maximum pressure specified for your column.

For the softer gels, Sephadex G-75–G-200, more care must be taken to avoid compressing the gel. Do not increase the pressure beyond the values given in Table 1.

With wider columns, slightly reduced maximum operating pressures must be used. Flow rate is inversely proportional to bed height: increasing the bed height will decrease the flow rate, but does not affect the maximum operating pressure.

1. Using a reservoir if necessary, pour the entire slurry into the column in one portion.

2. Start the pump to initiate packing.

3. Once all the gel has sedimented into the column, remove the reservoir.

4. Insert an adaptor and pack at the maximum operating pressure of the gel.

5. Once the gel is thoroughly packed into the column, adjust the flow adaptor to the surface of the gel bed.

6. Pass a further 2–3 column volumes of the buffer to be used in the separation. This stabilizes and equilibrates the bed.

7. Readjust the flow adaptor to the surface of the gel bed.

Cleaning

1. Wash with two column volumes of 0.2 M NaOH or a solution of a nonionic detergent. Washing the more porous Sephadex types (G-50–G-200) with NaOH should be done outside the column because the gel will swell.

2. Reequilibrate the gel with 2–3 column volumes of buffer before your next experiment. When necessary, the gel can be removed from the column and sterilized by autoclaving at 120 °C, pH 7.

storage

Store unused gel dry at 2–8 °C.

Store used gel at 2–8 °C in 20% ethanol or in a solution of a microbial growth inhibitor such as 0.002% Hibitane/chlorhexidine or 0.02% sodium azide.

 

 

sephadex G-25凝胶过滤填料

sephadex G-25凝胶过滤填料

 

 

上一篇:常温凝胶渗透色谱系统的使用注意事项 下一篇:凝胶渗透色谱的常见故障应该怎么解决
热线电话 在线询价
提示

请选择您要拨打的电话:

当前客户在线交流已关闭
请电话联系他 :