品牌
经销商厂商性质
上海市所在地
TEMATEC温度表701531/888-22
¥17000Tek-Air探头7128IPB00006
¥17000Sesino水冷却器AP2/680EMX
¥17000RF IDEAS支架RDR-6011AKU
¥17000Testra电机Testra减速机
¥17000仪器仪表机电设备
¥17000CTS移动导轨AG416RAG420仪器仪表机电设备
¥17000CTC调节器选型M105RGB14
¥17000Datasensor光幕939501110TC
¥17000EIKOH滤纸EIKOH空气过滤器
¥17000ELECO电源ELECO灯泡
¥17000ELVEM强制冷电机 132SB2B5
¥17000neff采板卡 neff机箱(含电源) neff逻辑板卡
The Neff Advantage
Since 1956
Located in Monrovia, California not far from Pasadena, NEFF Instruments has been a leading manufacturer of high performance data acquisition equipment since its founding in the mid 1950s by Glyn Neff.
System 470
System 620/600
System 471
System 472
System 730
System 495
System 470
Function Cards
DA23350
DA23535
6715450306
KAR-3-3205 KGF-N-3205/Tr 36x6
TGS-RPTS-Tr-36x6-LH-K82-A-462-0
89026352
9002335012
470100
9002335012
90023535
470051
TGS-RPTS-TR-28X5-T5-RH-1050
System 471 |
System 472 |
System 495 |
System 620/600 |
System 730 |
· The NEFF System 470 (S470) DAS is a complete, low cost moderate-speed DAS for use in computer-based applications. The S470 is designed primarily for computer automated data acquisition in test facilities, laboratories and industrial plants or wherever a moderate-speed DAS is required.
· The S470 is designed to accept analog inputs ranging from 5mV to 10.24V full scale in 12 programmable steps. Signal conditioning for sensors such as strain gages, RTDs, potentiometers and thermocouples is supplied by standard S470 function cards thus eliminating the need for external sources. Other function cards support digital I/O, frequency measurement and analog output.
· S470 consists of a 7-inch high, 19-inch wide enclosure with power supply, backplane wiring, I/O Control Logic printed circuit card, Analog Subassembly printed circuit card and 16 I/O card slots that accept any combination of S470 function cards. A Control/Display panel is optional and an expansion assembly is available to extend function card capacity to 32. The maximum number of channels or data points to be serviced depends on the type of function cards used. Thirty-two 16-channel Multiplexer cards, for example, provide 512 channels of analog input while a full complement of 32-bit TTL input cards accommodate 1024 single data points.
· The Series 600 is NEFF's top-of-the-line data acquisition system providing the utmost in performance, accuracy and convenience. Featuring leading-edge technology and innovative design, Series 600 brings extensive automation and complete programmability to the testing laboratory.
· The key to Series 600's high performance is the effective combination of fully programmable preamp/filters, programmable post amplifier, sophisticated microprocessor-controlled calibration circuits and the amplifier-per-channel data acquisition technique that realizes the lowest noise level and highest common mode rejection obtainable in a data acquisition system.
· Programmable Gain Over the Full Dynamic Range
With programmable gain, test setup time is greatly reduced as is the bother and confusion of manual switch settings. In Series 600 the range of each channel is programmable from +/-5mV full scale to +/-10.24V full scale in 12 binary steps.
· Preamps Include Programmable Filter
Two types of input preamps are available in Series 600 to allow both static and dynamic measurements. Both have programmable filter cutoff frequencies of 1Hz, 10Hz, 100Hz and 1kHz. Low-level differential preamps (620650 and 620654) have 2-pole and 6-pole Butterworth filters, respectively.
· The sample and hold preamp (620654) permits simultaneous sampling of multiple low-level input channels and is used where minimum channel-to-channel skew is required. both preamps have fully guarded inputs and operate from grounded or floating signal sources.
· Automatic Calibration
On command the internal microprocessor takes over control of the Series 600 and begins a sequence of steps to derive and store calibration factors for each channel. The calibration data is stored in on-board memories and during run mode are summed with the post amplifier output voltage to obtain fully calibrated signals for conversion by the ADC.
· The automatic calibration procedure results in static accuracy of (0.02%