英国Wayne Kerr 公司的WK-3260B测试分析仪,除基本的LCR及阻抗等测试功能外,还具备直流偏压和圈比测试,是一款偏重于变压器等磁性元件而设计的.由于测试精度高,功能多,方便操作,目前绝大多数客户都采用这种设备.相对于HP的测试仪器来讲,操作方便,易上手,精度高,更受工程师喜爱.配备的DC BIASzui大可到125A.
At the design stage of component development it is vitally important to understand how the component performs under different operating conditions. This might include operation at diverse frequencies, AC drive levels or DC bias currents.
The 3260B Precision Magnetics Analyzer can plot any of the measurement functions, such as inductance (L) or impedance (Z), (including secondary term) against frequency, AC drive level or DC bias current.
Frequency sweeps within the range 20 Hz to 3 MHz can be selected. There is a choice of either linear or logarithmic frequency displays.
3260B is especially suitable for measuring parameters on ecom transformers.
The selected measurement parameter and its secondary value are presented graphically. AC drive levels can be set between 1 mV and 10 V. DC bias current can be set from 1 mA to 1 A internally. Using external 3265B 25 A DC Bias Units bias currents can be set to a maximum of 125 A.
Measure Insertion Loss and Return Loss on ecom transformers
With the dramatic growth of PCs connected to the ephone system for Internet access has come the requirement to measure Insertion Loss (IL) and Return Loss (RL) of line matching transformers.
The 3260B Precision Magnetics Analyzer not only measures IL and RL has this capability. but the instrument also allows the user to enter the values for terminating resistance or impedance, if complex, and to select a damped network or blocking capacitor if required.
Specification summary
Measurement functions | Z, Ø, L, C, Rac, Rdc, Q, D Turns Ratio Primary and secondary Leakage Inductance Interwinding Capacitance Resonant Frequency |
Frequency ranges | 20 Hz to 3 MHz |
Basic accuracy | 0.1% |
Mode | Analysis (graphing) ecom Multi Frequency Sequence |
DC bias current | 1 mA to 1 A (internal) Up to 125 A (using five 3265B DC Bias Units) |
Interface | GPIB |
Measurement speed | Up to 20 measurements/sec |
Printed output of test results
Using the parallel Centronics interface the user can directly print test results including graphs for further analysis and archiving.
In addition, via the IEEE488 GPIB interface, the instrument can be controlled from a PC and results can be read back for analysis and storage. LabVIEW™ drivers are available upon request or may be downloaded from this website providing a base from which a user can develop a specific test application.
Bin sort
The bin sorting function allows component manufacturers to sort components in up to ten bins. Sorting is carried out either by absolute values or by percentage of values.
Component tests with up to 125 A DC bias current
3265B DC Bias Unit is used can deliver up to 25 A of DC bias current in steps of 0.025 A
To evaluate components at high currents up to 125 A the optional 3265B DC Bias Unit is used.
25 A of DC bias current can be set in steps of 25 mA with one unit whilst up to five units can be used in parallel to give up to 125 A DC bias current. The standard 3260B Precision Magnetics Analyzer can provide an internal DC bias from 25 mA to 1 A.
The 3265B has a number of safety and protection features including a safety interlock system to protect the user against back EMFs. It is also fully protected against over temperature,'excess voltage drop and sense lead failure.
SMD inductor tests up to 50 A
1009 DC Bias Fixture enables currents up to 50 A to be applied to an SMD inductor
With the addition of the 1009 DC Bias Fixture DC bias currents up to 50 A can be applied to an SMD inductor during component test in order to evaluate the devices thoroughly at the operational bias currents.
The fixture operates with one or two 3265B Wayne Kerr DC bias units and a 3260B Precision Magnetics Analyzer.
Four rear panel mounted BNC connectors and two captive high current cables ensure simplicity and ease of use with the 3265B.
Interchangeable component test carriers ensure that the 1009 DC Bias Fixture may be used with a wide variety of devices. If a device package is not supported by one of the standard carriers then a custom carrier design service is available.
Stable component fixturing ensures high accuracy and repeatable measurements. Enclosed fixtures, with safety interlocks, minimises risk to operators.
Technical Specifications
Operation modes
Impedance mode
Inductance (L), Impedance (Z), DC Resistance (Rdc) and Capacitance (C).
Series or parallel equivalent circuit
Loss term: Quality factor (Q),
Dissipation factor (D), AC Resistance (Rac) and Phase Angle (Ø)
Analogue scale (bar graph) with nominal, absolute and percentage% modes
Handler mode
Enables existing 4-wire scanners to be used
Functions as for impedance mode plus Turns Ratio
Transformer mode
Rdc of each winding, Primary or Secondary Leakage Inductance and Q, Turns Ratio, Interwinding Capacitance.
Insulation between windings from either winding to screen/core is available as an option.
ecom mode
Provides derivation of Insertion Loss (IL) and Return Loss (RL) for line matching transformers operating in the ephone speech band (100 Hz to 20 kHz). Values of line impedance (Zo) and termination (Rt) are user selectable. Optional simulated damping network and series blocking capacitor are user configurable.
Analysis mode
Measurement parameters and test conditions set using measurement mode.
Graphical sweep versus frequency, AC drive level or DC bias current with selection of start, stop, step size, units and linear/log.
Multi-frequency mode
Measurement parameters and test conditions set using measurement mode. Up to eight frequencies with absolute or percentage limits on major term PASS/FAIL indications.
Test conditions
Low level AC drive
For measurement of L + Q, Ls + Rs,
C, Z, Turns Ratio and Leakage Inductance
Frequency range
20 Hz to 3 MHz inter winding capacitance, minimum frequency 1 kHz
Steps
Increments of 1% or better across range with approximay 1800 frequencies.
Accuracy of selected frequency ±0.01 %
Drive level
Source impedance 50 Ω
1 mV to 10 V rms into open circuit
50 µA to 200 mA rms into short circuit
Automatic Level Control (ALC) maintains level applied to DUT at ±2%, ±1 mV of set voltage or ± 2% ±0.1 mA of set current.
DC bias current
1 mA to 1 A DC is available from internal, fast settling bias supply over full frequency range Voltage compliance 20 V minimum
Safety interlock minimises operator exposure to high currents.
DC resistance
Low test level of 100 mV minimises heating of the device under test.
Short circuit current 10 mA
Insulation (option)
Test voltages of 100, 200 or 500 V DC, user selectable
Results can be displayed as a current or resistance value
Voltage accuracy ±3%
For user safety, short circuit current is limited to <2 mA
Bin Handler mode (option)
Sort to 1 of 10 bins using absolute or percentage limits.
Separate Pass/Fail output.
Up to 100 bin limit set-ups stored in non-volatile memory.
TTL interface to external bin handler via 25 way D type connector.
ecom mode (option)
Drive level -28 to 16 dBm
Test time varies with level
Zo/Rt 50 to– 2000 Ω
Test time < 1.5 s typical
Measurement speeds
For impedance, turns ratio, DC resistance and insulation
4 speeds selectable: MAXimum, FAST, MEDium and SLOW
MAX (20 measurements per second) is for component sorting under IEEE 488.2 remote control.
FAST Approximay 10 measurements per second.
SLOW Approximay 1 per second for increased stability and accuracy
Measurement ranges
R 0.01 mΩ to >2 GΩ*
L 0.1 nH to >1000 H*
C 5 fF to >1 F*
Accuracy
Inductance/Rac/Z/Cp ±0.1 %**
Q ±0.1% (Q+1/Q)**
D ±0.001 (1+D2)**
Turns ratio ±0.1 %**
Rdc ±0.5 %
Insulation ±5 % (500 V test)
Insertion loss ±0.1 dB
Return loss ±1 dB
Basic accuracy varies with frequency, Zo, Rt, range and level.
General data
Input specification
Power supply 230V AC ±10% or 115V AC ±10% (selectable) 50 to 400 Hz
400 VA maximum consumption
Display
High contrast monochrome LCD 320 x 240 dot with CFL back lighting.
Visible area 115 x 86mm.
Viewing angle 45°
Measurement connections
8 front panel BNC sockets
2- or 4-wire (Kelvin) measurements with screen at ground potential
Equivalent circuit symbols on screen.
Separate terminals for primary and secondary connections. LEDs indicate active terminals.
Remote control (option)
Conforms with to GPIB (IEEE488.2) and SCPI 1992.0
Printer output
Centronics /parallel printer port
Ambient conditions
Operating temperature range 0°C to 40°C.
Full accuracy 15°C to 35°C
Safety
Complies with the requirements of EN61010-1
EMC
Complies with EN50081-1, EN50082-1 generic emissions and immunity standards by meeting with the requirements of EN55022, IEC801.2, IEC801.3 and IEC801.4
Mechanical (approx. overall)
Height 150 mm (6")
Width 440 mm (17 3/8")
Depth 520 mm (20 1/2½")
Weight 11 kg (24 lbs 4oz.)
Order codes and options
3260B Precision Magnetics Analyzer Supplied with user manual, power cable, spare fuses, power cable, two transfer standard capacitors and safety interlock. | 1J3260B | |
Options | ||
Insulation test (500V) | add /N to part number | |
Analysis function (graphs) | add /G to part number | |
LF ecom function | add /T to part number | |
Bin Handler | add /D to part number | |
Auxiliary unit | ||
25A DC bias unit 3265B (1 MHz) Supplied with user manual, power cable, spare fuses, 4 x BNC to BNC links, daisy chain link, rack mounting ears (unit needs rear support) and bus bars. | 1J3265B | |
25A DC bias unit 3265BQ (3 MHz) Supplied with user manual, power cable, spare fuses, 4 x BNC to BNC links, daisy chain link, rack mounting ears (unit needs rear support) and bus bars. | 1J3265BQ | |
Accessories | ||
1009 DC Bias Fixture | 1J1009 | |
Rack mounting kit, 3U x full width | 1EXA20230 | |
Kelvin clips (fine jaws). (2 sets recommended for transformer tests) | 1EVA40100 | |
Kelvin clips (large jaws) | 1EVA40180 | |
BNC to 4-terminal component fixture (Recommended above 500 kHz) | 1EV1006 | |
4-terminal lead set | 1EV1505 | |
SMD Tweezers | 1EVA40120 |