高精度功率计
测量精度指标(DC 0.5~2KHz)
参数 | 测量范围 | 误 差 | 备注 |
电压 | 波峰系数CF=3:40/600 波峰系数CF=6:20/300 | DC | ±(读数的0.1% +量程的0.2% ) | 0.5 Hz ≤ f< 45 Hz | ±(读数的0.1% +量程的0.2% ) | 45 Hz ≤ f ≤ 66 Hz | ±(读数的0.1% +量程的0.1 % ) | 66 Hz < f ≤ 1 kHz | ±(读数的0.1% +量程的0.2 % ) | 1 k Hz < f ≤ 2 kHz | ±(读数的0.15% +量程的0.3% ) |
| 过载: 1.1倍 |
电流 | 波峰系数CF=3:0.1/20(40仅限CF=1.5) 波峰系数CF=6:0.05/10(40仅限CF=1.5) |
有功 功率 | U*I | DC | ±(读数的0.1% +量程的0.2% ) | 0.5 Hz ≤ f< 45 Hz | ±(读数的0.3% +量程的0.2% ) | 45 Hz ≤ f ≤ 66 Hz | ±(读数的0.1% +量程的0.1 % ) | 66 Hz < f ≤ 1 kHz | ±(读数的0.2% +量程的0.2 % ) | 1 k Hz < f ≤ 2 kHz | ±(读数的0.2% +量程的0.3 % ) |
| PF=1.0 |
功率 因数 | 0.1 ~ 1 | 0.5 Hz ≤ f< 45 Hz | ±0.01 | 45 Hz ≤ f ≤ 66 Hz | ±0.01 | 66 Hz < f ≤ 1 kHz | ±0.02 | 1 k Hz < f ≤ 2 kHz | ±0.05 |
|
|
频率 | 0.5 ~ 2kHz | 计数方式,0.1%*读数,当信号值大于0.1*当前量程 |
|
电能 累计 | 0~999999 MWh /0~-99999 MWh | DC | ±(读数的0.1% +量程的0.2% ) | 0.5 Hz ≤ f< 45 Hz | ±(读数的0.3% +量程的0.2% ) | 45 Hz ≤ f ≤ 66 Hz | ±(读数的0.1% +量程的0.1% ) | 66 Hz < f ≤ 1 kHz | ±(读数的0.2% +量程的0.2% ) | 1 k Hz < f ≤ 2 kHz | ±(读数的0.2% +量程的0.3% ) |
|
|
安时 累计 | 0~999999 MAh /0~-99999 MAh | DC | ±(读数的0.1% +量程的0.2% ) | 0.5 Hz ≤ f< 45 Hz | ±(读数的0.1% +量程的0.2% ) | 45 Hz ≤ f ≤ 66 Hz | ±(读数的0.1% +量程的0.1% ) | 66 Hz < f ≤ 1 kHz | ±(读数的0.1% +量程的0.2% ) | 1 k Hz < f ≤ 2 kHz | ±(读数的0.15%+量程的0.3% ) |
|
|
电能计时 | 99999h | ± 2秒/小时 |
|
谐波 | 1~50次 | 基波频率 | zui高分析次数 | 10Hz~65Hz | 50 | 65Hz~100Hz | 32 | 100Hz~200Hz | 16 | 200Hz~400Hz | 8 |
| 精度等级:B级 |
二 其它技术指标
显示更新:显示刷新周期0.1秒~5秒可设。
整机功耗:< 10VA;
仪表重量:约 2.8kg;
仪表外形zui大尺寸:宽×高×深 (223.5×107.5×380);
仪表开孔尺寸:宽×高(209×84)。
三 工作环境
大气压力:(86~106)kPa ;
温度:(0~40)℃ ;
相对湿度:≤85%RH
仪表工作电源:AC (100~265)V 50/60Hz
四 安全要求
绝缘电阻:下列端子间绝缘电阻不低于2MΩ;
耐 电 压:下列端子之间能承受2000V 50Hz正弦波电压:
测量端子与机壳之间;电源线与机壳之间;测量端子与电源线之间。