Model | 6605 | 6610 | 6620 | 6630 | 6650 |
INPUT |
Phase | 1Ф |
Voltage | 110 / 220Vac±10% | 220±10% |
Frequency | 47 - 63Hz |
Max. Current | 10A / 5A | 20A / 10A | 20A | 30A | 50A |
Power Factor | 0.7 |
AC OUTPUT |
Max. Power | 500VA | 1000VA | 2000VA | 3000VA | 5000VA |
Max. Current (r.m.s)*1 | 0-150V | 4.6A | 9.2A | 18.4A | 27.6A | 46.0A |
0-300V | 2.3A | 4.6A | 9.2A | 13.8A | 23.0A |
Max. Current(peak) | 0-150V | 18.4A | 36.8A | 73.6A | 110.4A | 184.0A |
0-300V | 9.2A | 18.4A | 36.8A | 55.2A | 92.0A |
Phase | 1Ф / 2W |
Total Harmonic Distortation (T.H.D) | <0.5% at 40 - 100Hz, <1% at 101 - 500Hz (Resistive Load) |
Crest Factor | ≧3 |
Line Regulation | ± 0.1V |
Load Regulation | ± (0.5% of output +0.5V) at Resistive Load |
Response Time | <400µsec |
SETTINGS |
Voltage | Range | 0-300V, 150V / 300V Auto Range |
Resolution | 0.1V |
Accuracy | ±(1% of setting + 2counts) | ±(1% of setting + 5counts) |
Frequency | Range | 40-500Hz Full Range Adjust |
Resolution | 0.1Hz at 40.0-99.9Hz , 1Hz at 100-500Hz |
Accuracy | ±0.03% of setting |
Starting& Ending Phase Angle | Range | 0-359° |
Resolution | 1° |
Accuracy | ±1°(45 - 65HZ) |
DC OUTPUT (Option) |
MAX. Power | 250W | 500W | 1000W | 1500W | 2500W |
Max. Current | 0-200V | 2.3A | 4.6A | 9.2A | 13.8A | 23.0A |
0-400V | 1.15A | 2.3A | 4.6A | 6.9A | 11.5A |
SETTING |
Voltage | Range | 0-200V / 0-400V Selectable |
Resolution | 0.1V |
Accuracy | ±(1% of reading + 2counts) | ±(1% of reading + 5counts) |
Ripple and Noise (r.m.s) | Range | L | < 250mV | < 350mV |
H | < 400mV | < 550mV |
Ripple and Noise (p-p) | <2Vp-p | <3.0Vp-p |
MEASUREMENT |
Voltage (AC & DC) | Range | 0.0-400.0V |
Resolution | 0.1V |
Accuracy | ±(1% of reading + 2counts) | ±(1% of reading + 5counts) |
Frequency | Range | 0.0-500.0Hz |
Resolution | 0.1Hz |
Accuracy | ±0.1Hz |
Current (r.m.s) | Range | L | 0.005A - 0.600A | 0.005A - 1.200A | 0.005A - 2.400A | 0.005A - 3.600A | - |
H | 0.50A -6.50A | 1.00A -13.00A | 2.00A -26.00A | 3.00A - 39.00A | 0.00 - 65.00A |
Resolution | L | 0.001A |
H | 0.01A |
Accuracy | L | ±(1% of reading +5counts) | ± (1% of reading + 5 counts) at 40 - 100Hz ± (2% of reading + 5 counts) at 101 - 500Hz |
H | ±(1% of reading +5counts) |
Current(peak) | Range | 0.0 - 19.0A | 0.0 - 38.0A | 0.0 - 76.0A | 0.0 - 114.0A | 0.0 - 190.0A |
Resolution | 0.1A |
Accuracy | ±(1% of reading + 5counts) |
Current (DC) | Range | L | 0.010A - 0.600A | 0.010A - 1.200A | 0.010A - 2.400A | 0.010A - 3.600A | - |
H | 0.50A - 6.50A | 1.00A - 13.00A | 2.00A - 26.00A | 3.00A - 39.00A | 0.05A - 65.00A |
Resolution | L | 0.001A |
H | 0.01A |
Accuracy | L | ± (1% of reading + 5 counts) |
H | ± (1% of reading + 5 counts) |
Power (AC) | Range | L | 0.0W - 60.0W | 0.0W - 120.0W | 0.0W - 240.0W | 0.0W - 360W | - |
H | 50W - 650W | 100W - 1300W | 200W - 2600W | 300 - 3900W | 0 - 6500W |
Resolution | L | 0.1W |
H | 1W |
Accuracy | L | ± (2% of reading + 15 counts) | ± (2% of reading + 30 counts) | ± (2% of reading + 15 counts) at PF>=0.2 and 40 - 100Hz ± (2% of reading + 15 counts) at PF>=0.5 and 101 - 500Hz |
H | ± (2% of reading + 5 counts) | ± (2% of reading + 10 counts) | ± (2% of reading + 5 counts) |
Power (DC) | Range | L | 0.0W - 60.0W | 0.0W - 120.0W | 0.0W - 240.0W | 0.0W - 360W | - |
H | 50W - 650W | 100W - 1300W | 200W - 2600W | 300 - 3900W | 0 - 6500W |
Resolution | L | 0.1W |
H | 1W |
Accuracy | L | ± (2% of reading + 5 counts) |
H | ± (2% of reading + 5 counts) |
Power Factor | Range | 0.000-1.000 |
Resolution | 0.001 |
Accuracy | W / VA ,Calculated and displayed to three significant digits |
GENERAL |
Remote Input Signal Interface(Option) | Test, Reset, Recall memory 1 through 7 |
Remote Output Signal | Pass, Fail ,Test-in Process |
Memory | 50 memories, 9 steps/memory |
Sync Output Signal | DC Level 5V |
Timer | 0=Continuous, 0.5-999.9 (Unit: sec, minute, hour selectable) |
Alarm Volume Setting | Range: 0 - 9; 0=OFF, 1 is softest volume, 9 is loudest volume |
Graphic Display | 240 x 64 dot resolution Monographic LCD / Contrast 9 Levels 1 - 9 |
Auto loop cycle | 0=Continuous, OFF, 2~9999 |
Over Current Fold Back | On/Off, Setting On when output current over setting Hi-A value it will fold back output voltage to keep constant output current is setting Hi-A value |
Efficiency | ≥80%(at Full Load ) |
Protection | Over Current, Short Circuit, Over Temperature, Over Voltage, Over Power, and Alarm |
Calibration | Front Panel Calibration |
Interface (Option) | GPIB, USB & RS232, PLC Remote Input Card |
Operation Environment | 0-40℃/20-80%RH |
Dimension, mm*2 | W | 430 | 430 | 430 | 430 | 430 |
H | 89 (115.5) | 89 (111.5) | 89 (111.5) | 223 (245.5) | 223 (245.5) |
D | 400 | 400 | 500 | 500 | 500 |
Net Weight | 16.5Kg | 18.2Kg | 30Kg | 57Kg | 65Kg |
*1 At working voltage 110V / 220V | *Product specifications are subject to change without notice. |
*2 Figure in parentheses are maximum values |