Prosim 8,专业质控代表。他多功能,可以同时模拟8种生命体征:心电信号、呼吸信号、无创血压信号、血氧饱和度信号、有创压信号双通道、心输出量、温度信号、Rainbow技术。他更专业,可详细设置各种参数,满足专业检测要求。他易操作,全中文大屏幕显示,即插即用。他率,用户定义自动检测序列,提高检测效率。
Model Name | Description |
ProSim 8 (3979409) | ProSim 8 Vital Signs Simulator US Includes:
|
ProSim 8-01 (3979411) | ProSim 8 Vital Signs Simulator Schuko Includes:
|
ProSim 8-02 (3979427) | ProSim 8 Vital Signs Simulator UK Includes:
|
ProSim 8-03 (3979430) | ProSim 8 Vital Signs Simulator Japan Includes:
|
ProSim 8-04 (3979448) | ProSim 8 Vital Signs Simulator Australia Includes:
|
ProSim 8-05 (3979453) | ProSim 8 Vital Signs Simulator Brazil Includes:
|
ProSim SPOT (3985658) | ProSim SpO2 Test Module |
ProSim RAINBOW (4034609) | ProSim RAINBOW Test CABLE |
Cables (IBP) | |
3010-0104 | 3010-0104 EM-1 BP cable (6ft) (6-pin) (part# 2198893) For use with the following: •GE Marquette Medical (PPG/E for M DR) •Witt Biomedical •Schiller PB Series |
3010-0208 | Nihon Kohden-NK-1 BP cable (5M) (5-pin) (part# 2462263) (Requires Nihon Kohden Smart IBP Cable JP-910P for latest series TR-6000 and minDin to DIN adapter) |
3010-0103 | 3010-0103 Datascope DS-1 BP cable (6F) (part# 2198887) |
3010-0307 | Fukuda Denshi (DS3300 series) FD-2 BP cable (12M) (12-pin orange) (part# 2199387) |
3010-0357 | GE Marquette Medical (Dash, Eagle, Solar, Tram and MacLab) MQ-3 BP cable (rectangular -11 M) (part# 2199627) |
3010-0110 | HP-3 BP cable (12M 5µV) 120 in, Mini-DIN to 12 pin HP/PH (part# 2198902) For use with the following: •Hewlett Packard/Philips (78-300, 78-500, 78-800, Merlin/Viridia/Omnicare) (HP/Philips M1006B iBP module has a sensitivity of 5 uv/V/mmHg only. Select the HP-3 cable for this application) |
3010-0111 | HP-4 BP cable (12M 40µV) for ProSim 8, MedSim 300B, 217A (part# 2198916) connecting to Hewlett Packard/Philips (78-300, 78-500, 78-800, Merlin/Viridia/Omnicare) |
3010-0115 | Mennen Medical (Horizon series) MM-1 (6M) (6-pin) (part# 2198933) |
3010-0122 | GE Marquette Medical (7000 and TRAM-AR series only) MQ-2 (8M round) (7-pin) (part# 2198978) |
MiniDIN/DIN IBP | Mini DIN to DIN IBP Adapter (part# 3408564) •Nihon Kohden Used to adapt PS420 or MPS450 blood pressure cables for use with ProSim series simulators. |
3010-0116 | PC-1 BP cable (6M) (6-pin) (part# 2198940) For use with the following: •Physio Control (VSM series) •Medical Data Electronics (Escort series) |
3010-0584 | DX-1 BP cable (10F) (10-pin) (part# 2200955) Used with the following: •Puritan Bennett PB 240 •Datex (AS/3, CS/3, Compact, Cardio Cap II, Critical Care, Light) |
3010-0248 | QM-1 (6M) Blood pressure cable (10-pin orange) (part# 2198925) for use with the following: •Quinton (Q Cath series) •Drager/Siemens (Some of Drager/Siemens monitors use the standard 10 pin Siemen connector, but newer models require Drager's IBP Adapter 10 to 7 pin. Drager PN: 3368383) |
3010-0366 | SM-3 BP cable (15M) (part# 2199666) •Siemens (Micor/Mingo) |
3010-0114 | SM-1 BP cable (10M) for Pro Sim 2/3, 4 or ProSim 8 (10-pin) (part# 2198925) •Drager/Siemens (SIRECUST series) (Use the SM-1 and the Siemens Medical Transducer Adapter (3368-383-E530U) to run a single invasive BP channel on the Siemens Medical SC6000 and SC9000 series monitors) |
3010-0076 | 3010-0076 TK-1 (6M) BP Cable (part# 2198879) applies to: • BCI International • Criticare Systems Inc. (1100) • Critikon (Dinamap Plus) • Invivo Research • Ivy Biomedical (400 and 700 series) • North American Draqer (Vitalert 2000) • Protocol System (Propaq series) Zoll Defib • SpaceLabs (1050, 1700, PCMS series) (SpaceLabs adapters 700-0028-00 and 0120-0551-00 with TK1 used when testing the new UltraView Command Module) |
3010-0048FG | Universal unterminated UU-1 BP cable (5-Pin DIN one end only) (part# 2392173) |
ProSim 8 Cable Kits | |
3984993 PS8 DRAGER CABLES | Dräger Infinity Cable Set (part# 3984993) for ProSim 8 includes: •SM-1 BP Cable (part# 2198925, two) •UT-4,Low profile 1/4 inch phone plug •YSI 400 Series Compatible 2 conductor (part# 2523334) |
3984968 PS8 GE CABLES | GE Marquette Eagle/Dash/Solar Cable Set (part# 3984968) for ProSim 8 includes: •MQ-3 BP Cable (part# 2199627, two) •UT-4,Low profile 1/4 inch phone plug •YSI 400 Series Compatible 2 conductor (part# 2523334) •UT-2 Tamp Cable 700 Series YSI (part# 2199019) •PROSIM8-4402GECO Din cardiac Output Marq Eagle (part# 4022300) |
3984922 PS8 HP/PHI CABLES | HP/Philips Inlivue Cable Set (part# 3984922) for ProSim 8 includes: •HP-3 BP Cable (part# 2198902, two) •HPT-2 Tamp/C.O. Injct Cable Assembly (part# 2199257) •COA-1 Cable Assembly (part# 2199240) •UT-4,Low profile 1/4 inch phone plug •YSI 400 Series Compatible 2 conductor (part# 2523334) |
3985009 PS8 NK CABLES | Nihon Kohden Cable Set (part# 3985009) for ProSim 8 includes: •Nihon Kohden-NK-1, BP Cable (5M) (part# 2462263, two) •DIN to minDin adapter (part# 3408564) •UT-4, Low profile 1/4 inch phone plug •YSI 400 Series Compatible 2 conductor (part# 2523334) |
3984910 PS8 ACC KIT | ProSim 8 Accessory Kit (part# 3984910) includes: •DIN to minDin adapter (part# 3408564) •HP/Philips Inlivue IBP cable (part# 2198902) •GE Marquette Eagle/Dash/Solar IBP cable (part# 2199627) •Welch Allyn Propaq/SpaceLabs Ultraview IBP cable(part# 2198879) •USB wireless dongle (part# 3341333) •YSI400 series temperature cable (part# 2523334) •YSI700 series temperature cable (part# 2199019) •CI-3 Cardiac Output Box (part# 2392199) •spare battery pack (part# 4021085) |
3984946 PS8 SPACEL CABLES | SpaceLabs Ultraview Cable Set (part# 3984946) for ProSim 8 includes: •TK-1 BP Cable (part# 2198879, two) •UT-4,Low profile 1/4 inch phone plug •YSI 400 Series Compatible 2 conductor (part# 2523334) •UT-2 Tamp Cable 700 Series YSI (part# 2199019) •CI-3 Cable Assembly (part# 2392199) |
3984979 PS8 WA/PRO CABLES | Welch Allyn/Propaq Cable Set (part# 3984979) for ProSim 8 includes: •TK-1 BP Cable (part# 2198879, two) •UT-4,Low profile 1/4 inch phone plug •YSI 400 Series Compatible 2 conductor (part# 2523334) •UT-2 Tamp Cable 700 Series YSI (part# 2199019) |
Batteries, Chargers, and Power Supply | |
BPPS68 | ProSim 6/8 Battery Pack |
Cables | |
4034393 | Data Transfer Cable for use with ProSim 4, ProSim 8, ESA615 |
3010-0284 | COA-1 Cardiac output adapter (Hewlett Packard) 1/4 Phone plug to 4 pin female audio connector (HPT-2 also required for cardiac output simulation on HP patient-monitoring systems) (part# 2199240) |
3010-0285 | HPT-2 temperature adapter (2 pin) (part# 2199257) (Hewlett Packard/Philips)(used with UT-1 for HP monitors) (COA-1 also required for cardiac output simulation on HP patient-monitoring systems) |
ProSim8-4402GECO | ProSim8-4402GECO Cardiac Output Switch for GE (Marquette Eagle) (part# 4022300) for use with ProSim 2/3 and ProSim 8 |
3010-0193 | UT-2 Standard 1/4" phone plug (compatible with YSI 700 series – 3 conductor) temperature cable (part# 2199019) Use with the following: •Spacelabs Ultraview (use adapter# 700-0031-00) •GE Marquette (use adapter# 402015-005 or 402015-004) •Welch Allyn/Propaq |
UT-4 | UT-4 Low profile, ¼ in phone plug, YSI 400 series compatible, two conductor (part# 2523334 or 3015280) •HP/Philips •SpaceLabs Ultraview (adapter# 700-0031-00) •GE Marquette Eagle/Dash/Solar (adapter# 402015-005 or 402015-004) •Drager Infinity •Welch Allyn/Propaq •Nihon Kohden (requires Nihon Kohden Smart Temperature Cable K961 for the latest series TR-6000) |
Miscellaneous Accessories | |
2719-0153FG | 4-pin female audio connector (part# 2392158) General purpose cardiac device output connector |
3010-0289FG | CI-3 Cardiac output test module (part# 2392199) |
PROSIM 6/8 CASE | ProSim CARRYING CASE (part# 4034597) |
MANDREL-5001 | ProSim NIBP Mandrel Set (part# 4308086) |
ProSim Chamber | NIBP Test 500ML Rigid Chamber (part# 4034611) |
Software | |
Ansur PROSIM 6/8 | Ansur ProSim6/8 Plug-In license (part# 4034627) |