Dr.Maisch/德国迈可 品牌
生产厂家厂商性质
上海市所在地
Cholesterolesters
面议Catecholamines/Catecholamine Metabolism Acids
面议Nucleic Acid Components
面议Proteins
面议Amino Acids and Peptides
面议Chiralic Analysis
面议Determination of Organic Acids, Carbohydrates, and
面议Cation Exchangers
面议Anion Exchanger SAX W Quick Columns
面议Anion Exchanger RP NN (Rapid Determination of Nitr
面议Anion Exchanger SAX NN (Rapid Determination of Nit
面议Anion Exchanger SAX W33 (Ascorbic Acid)
面议Analysis of Pharmaceuticals with UltraSep ES MLD | ||
UltraSep ES MLD | ||
MLD packings (MLD = monolayer dense) are very stable solide supports, known in the literature as "mixed self-assembled monolayers (SAM)”. They can be used both for basic and acidic compounds in a relatively wide range of pH and with high selectivity. The buffer concentration can be held less. With organic buffers one can successfully use these columns between pH 2 – 11. The application MLD1 demonstrates a separation on UltraSep ES MLD RP18, which was performed already on UltraSep ES PHARM RP8E with 15 mM phosphate buffer as eluent (Application PHARM3). With UltraSep ES MLD RP18 already £ 5 mM phosphoric acid is sufficient for delivering the same chromatogram quality (Application MLD2). Furthermore it is important that for obtaining comparable short retention times of basic pharmaceuticals one can work with 50% acetonitrile (instead of 30%). The application MLD3 represents a chromatogram of basic pharmaceuticals at pH 11, which was obtained after flushing the column with 6000 ml eluent, pH 11, corresponding to a continuous use of approximay 4 weeks. Remarkable is the still very good peak shape especially of perazine dimalonate. For working with basic eluents the usage of organic buffers and the addition of organic solvents is recommended. MLD packing are, as already mentioned, suitable for the separation of organic acids too (Application MLD4). Using MLD packings it is possible to obtain chromatograms with good peak shapes of very different classes of compounds (Application MLD5). | ||
| Examples of Analyzed Compounds | Analyzed in Application | Go to |
Acetic acid | MLD4 | MLD1 | |
Amitriptyline | MLD3 | ||
Chloramphenicol | MLD5 | MLD2 | |
Clozapin | MLD1, MLD2, MLD3 | ||
Diphenhydramine | MLD3 | MLD3 | |
Flecainide | MLD1, MLD2, MLD3 | ||
Formic acid | MLD4 | MLD4 | |
Mexiletine | MLD1, MLD2 | ||
Perazine dimalonate | MLD3 | MLD5 | |
Protriptyline | MLD1, MLD2 | ||
Sulfadimethoxine | MLD5 | ||
Sulfathiazole | MLD5 |
COLUMNS and PRICES (€) | ||||
Column size (mm) | ||||
200 x 3 | 200 x 2 | 150 x 3 125 x 3 | 150 x 2 125 x 2 | |
UltraSep ES MLD (RP8 or RP18 5 µm) | 280.00 | 280.00 | 255.00 | 255.00 |
Size (mm) | ||||
10 x 3 | 10 x 2 | |||
Precolumn cartridges (Price per pack = 5 pieces) | 170.00 | 170.00 |