进口SEC铅酸蓄电池SEC-12-UPS-500 12V141AH
进口SEC铅酸蓄电池SEC-12-UPS-500 12V141AH
进口SEC铅酸蓄电池SEC-12-UPS-500 12V141AH
进口SEC铅酸蓄电池SEC-12-UPS-500 12V141AH
进口SEC铅酸蓄电池SEC-12-UPS-500 12V141AH

SEC-12-UPS-500进口SEC铅酸蓄电池SEC-12-UPS-500 12V141AH

参考价: 面议

具体成交价以合同协议为准
2020-11-02 15:04:23
504
属性:
供货周期:现货;
>
产品属性
供货周期
现货
关闭
北京恒泰正宇科技有限公司

北京恒泰正宇科技有限公司

免费会员10
收藏

组合推荐相似产品

产品简介

进口SEC铅酸蓄电池SEC-12-UPS-500 12V141AH
公司致力为UPS电源 直流屏 通信 医疗等行业领域提供专业全方面的解决方案与服务

详细介绍

进口SEC铅酸蓄电池SEC-12-UPS-500 12V141AH

进口SEC铅酸蓄电池SEC-12-UPS-500 12V141AH

   

 

 

 

阀控式铅酸实心SEC Microlyte MP系列是一个典型的终端AGM电池。他们被设计成符合成本效益,但对于许多使用可靠的解决方案,设计铅钙板给他们一个三重效益。这些AGM电池提供竞争性的电池解决方案,结合上级气体复合技术和伟大的能量密度。可靠、多功能和维护自由——这是一个很难击败的选项!

The Microlyte MP series 5G、大数据、人工智能等技术都对数据处理和网络带宽有了更高要求,数据中心需要不断提升网络带宽去满足,所以数据中心这段时间对提升网络带宽有迫切需求,尤其是互联网的数据中心。提升网络带宽直接的方式就是提升单端口的网络带宽,从40G提升到100G,从100G到200G,甚至更高,从而将整个数据中心的带宽提升起来。已经有专,大多数400GbE部署将在2019年开始,400GbE交换机将作为超大规模数据中心的脊柱或核心交换机,以及私有和公共云数据中心的脊柱或主干交换机启动,要知道100G也才普及两三年,现在就要过渡到400G,网络带宽提升速度越来越快。

一面是数据中心对高速模块的强烈需求,一面是模块故障率居高不下。相比1G、10G,40G、100G甚至200G,直观感受故障率要高得多。当然,这些高速模块的工艺复杂度远比低速高,比如一个40G光模块,本质上就是通过4个10G通道绑定起来,同时工作实现的,相当于4个10G在工作,只要有一路有问题,整个40G就无法再用了,故障率当然要比10G高,而且光模块还要实现4条光路的协调工作,出错概率自然更高。100G更是如此,有的就是通过10个10G通道绑定起来,还有的采用新的光技术,这些都会增加出错可能。更高速率的更不用提了,技术成熟度上就不高,像400G仍是实验室里的技术,2019年就要推向市场,必然出现一次故障率的小高潮,好在刚开始用量不会很多,随着技术的不断提升,相信也会像低俗模块那样逐渐稳定。试想20年前拿到GBIC的1G光模块去用,和现在用200G的感觉差不多,新品短期内故障率升高是必然。

好在,光模块的故障对业务冲击较小,数据中心的链路都是有冗余备份的,一条链路光模块出问题,业务可走其它链路,如果是CRC错包也可通过网管立即发现,及早做更换处理,所以光模块故障很少对业务有较大影响,极少数情况下,可能因为光模块引发设备端口故障,从而导致整个设备挂掉的情况,这种情况多是设备实现不合理导致的,很少出现,绝大多数的光模块和设备之间是松耦合的,虽然连接在一起,并没有耦合关系。所以虽然高速光模块使用中坏的比较多,但对业务冲击也没那么大,一般不会引起人们重视,发现故障直接更换掉,高速光模块的维保时间也长,故障了基本是免费的更换,损失也不大。Float life: 8-years in float service @ 25°C (For 35Ah to 275Ah) Cycles: 200 cycles @ 80% DOD @ 25°C MP The Microlyte MP is a sealed, valve regulated AGM rechargeable Lead Acid battery that allows safe, trouble-free operation in any position. There is never any requirement to top up the electrolyte because over 99% of gases generated in normal operation are recombined inside the battery. The MP is sealed with the exception of a one-way valve that opens when excess pressure builds up inside the battery. This controls the internal pressure of the battery, optimises the efficiency of the recombination reaction and minimises the loss of electrolyte as Hydrogen and Oxygen. These features come together to make for a long-lasting, safe and reliable power source. By marrying cutting-edge technology and the world’s best components, we make industrial batteries that dominate the global market. This allows us to supply our distribution partners with world-class products quickly, and for less than other tierone brands. The MICROLYTE MP is constructed with the highest regard to quality. Our engineers use high-purity, virgin Lead for the active components and the best possible raw materials for all other battery parts to build a high energy density battery. The MP is assembled in a tough, non-conductive casing that’s resistant to high impact. The battery can be stored for long periods of time without charge, and shipped by sea, road or air without special precaution.

 

  理解和证券交易委员会是一个公司

  能满足各种需求的工业备用

  应用程序。我们是值得信赖的供应商的能量

  许多工业设施的存储设备

  在范围内。交会的产品范围线

  和超过1000个铅酸,镍镉,锂离子

  产品可以提供每光模块的故障多表现在端口无法UP、光模块无法识别、端口CRC错包等现象,这些故障与设备侧、光模块本身和链路质量都有些关系,尤其是错报和无法UP,很难从软件技术上判断故障位置。有些还是适配类的问题,双方都没有问题,只不过相互之间没有调试和适配过,导致无法在一起工作,这种情况还不少,所以不少的网络设备都会给出适配的光模块清单,要求客户用自己适配过的光模块,这样才能保证稳定可用。若遇到了故障,用的方法依然是轮换测试,换链路光纤、换模块,换端口,通过这一系列测试确认到底是光模块问题,还是链路或设备端口问题,好在一般这类故障现象比较确定,遇到那种故障现象不固定的就难处理了。比如端口上有CRC错包,将光模块直接拔出来换一个新的,故障现象消失,再将原来的光模块换回来,故障不再复现,这就不好判断到底是不是光模块问题。这种情况在实际使用中也会经常碰到,这让人难做判断。个电池操作

  需要。我们所有的电池工业规模持续

  12年或者更多,很多只要20年。

上一篇:铅蓄电池行业定义及分类 下一篇:铅蓄电池维护保养技巧分析
热线电话 在线询价
提示

请选择您要拨打的电话:

当前客户在线交流已关闭
请电话联系他 :