Dionex CarboPac PA100 糖类分析色谱柱

Dionex CarboPac PA100 糖类分析色谱柱

参考价: 面议

具体成交价以合同协议为准
2019-11-12 15:54:24
2264
属性:
供货周期:现货;规格:4 x 250 mm;货号:043055;应用领域:医疗卫生,环保,食品,化工,石油;
>
产品属性
供货周期
现货
规格
4 x 250 mm
货号
043055
应用领域
医疗卫生,环保,食品,化工,石油
关闭
北京豫维科技有限公司

北京豫维科技有限公司

中级会员8
收藏

组合推荐相似产品

产品简介

Dionex CarboPac PA100 糖类分析色谱柱
用于从糖蛋白中切下的低聚糖、中性和有唾液酸的N-连接低聚糖

详细介绍

Dionex CarboPac PA100 糖类分析色谱柱

用途和特点:
CarboPac PA100用于从糖蛋白中切下的低聚糖、中性和有唾液酸的N-连接低聚糖;单糖连接多聚糖的异构体;线性多聚糖剖面等的分离。

 

Dionex CarboPac PA100 糖类分析色谱柱

订货信息:

Dionex CarboPac PA100 糖类分析柱

分析柱
CarboPac PA100 Analytical Column (2 x 250 mm)057182
CarboPac PA100 Analytical Column (4 x 250 mm)043055
CarboPac PA100 Column (9 x 250 mm)SP2089
CarboPac PA100 Column (22 x 250 mm)SP2667
保护柱
CarboPac PA100 Guard Column (2 x 50 mm)057183
CarboPac PA100 Guard Column (4 x 50 mm)043054

 

 

Low-Picomole Oligosaccharide Analysis

Oligosaccharides released from therapeutic glycoproteins can differ in size, charge, branching, and linkage. Oligosaccharides with these features can be resolved using the CarboPac? PA100. It provides the flexibility to separate oligosaccharides into broad classes depending upon the degree of sialylation, while maintaining the resolution needed for routine analysis based on linkage isomerism. Coupled with pulsed amperometric detection, the PA100 supports detection at low-picomole levels.

The CarboPac PA100 column is a high-resolution, strong anion-exchange column for enhanced chromatography of oligosaccharides.

The Carbohydrate Membrane Desalter can be used on-line prior to fraction collection.

 

CarboPac PA100 Column for Oligosaccharide Analysis Specifications
DimensionsCarboPac PA100 Analytical Column:
4 × 250 mm
CarboPac PA100 Guard Column:
4 × 50 mm
CarboPac PA100 Microbore Column:
2 × 250 mm
CarboPac PA100 Microbore Guard Column:
2 × 50 mm
CarboPac PA100 Semipreparative Column:
9 × 250 mm
CarboPac PA100 Semipreparative Column:
22 × 250 mm
Maximum operating pressure4000 psi (27.9 MPa)
Temperature range4–60 °C
Recommended operating temperature: ambient
Typical operating conditions2400 psi at 1.0 mL/min (analytical and guard columns)
Recommended flow rate: 1.0 mL/min
Mobile phase compatibilitypH 0–14; 100% compatible with common organic solvents.
Ionic form eluents: sodium acetate and sodium hydroxide only.
Resin composition8.5-μm-diameter ethylvinylbenzene/divinylbenzene substrate (55% cross-linking) agglomerated with 275-nm MicroBead? quaternary amine functionalized latex (6% cross-linked).
Anion-exchange capacityApproximately 90 μeq/column (4 × 250 mm analytical column)
Column constructionPEEK with 10-32 threaded ferrule-style end fittings.
All components are nonmetallic.