87000/DWPMassChrom® Vitamins B1 and B6 in Whole Blood, with 96 Deep Well Plate
CHROMSYSTEMS 品牌
代理商厂商性质
所在地
温馨提示:仅用于科研,不可用于临床治疗
祥生兴业
480 Tests
Fast and easy sample preparation
Robust method with high selectivity
Short run time of 2.5 minutes
Isotopically-labelled internal standard for each analyte
With 96 deep well plates
Vitamin B1 (thiamine) plays an important role in deriving energy from carbohydrates and fats. The active form is thiamine pyrophosphate (TPP), a coenzyme for some enzymatic reactions in carbohydrate metabolism and for pyruvate decarboxylase. TPP is also significantly involved in the oxidative degradation of glucose. The determination of the TPP concentration is more significant than measurements of total thiamine, as by this method only the physiologically active form is taken into account.
Vitamin B6 comprises pyridoxine, pyridoxamine and pyridoxal, as well as their phosphate derivatives. It is ingested with food and transferred via several enzymatic conversions into its active form, pyridoxal-5’-phosphate (PLP). PLP is involved in nearly one hundred different enzymatic reactions, among other things, as co-factor in amino acid metabolism, and in the formation of haemoglobin or neurotransmitters in the brain.
This Chromsystems assay enables combined determination of the active forms of vitamin B1 (thiamine pyrophosphate, TPP) and vitamin B6 (pyridoxal 5‘-phosphate, PLP) in whole blood by LC-MS/MS. Sample preparation consists of a simple protein precipitation step, with no need for derivatisation. This makes for a much faster sample preparation and high sample throughput. Analytes and potential interferences are effectively and swiftly separated within 2.5 minutes, indicating the method's high selectivity and speed. The chromatographic separation of the MassChrom® assay is fast enough to ensure a high throughput in the laboratory, but sufficiently resolving for a clear separation of the two analytes with minimal potential matrix effects. Isotope-labelled internal standards for both parameters as well as 6PLUS1® calibrators and MassCheck® controls ensure accurate and precise results. The assay is available in 2 configurations either with reaction vials or with 96 deep well plates.
3.4 μg/l TPP
2.8 μg/l PLP
850 μg/l TPP
1000 μg/l PLP
Components available separately
Order no.: 87001
DETAILS
Order no.: 87002
DETAILS
Order no.: 87046
DETAILS
Order no.: 87005
DETAILS
Order no.: 87009
DETAILS
Order no.: 87057
DETAILS
Order no.: 87058
DETAILS
Order no.: 87059
DETAILS
Order no.: 87100
DETAILS
Order no.: 87018
DETAILS
Order no.: 87015
DETAILS
Order no.: 87019
DETAILS
Calibrators available separately
Order no.: 87039
DETAILS
Controls available separately
DETAILS