Phoenix Contact/菲尼克斯 品牌
代理商厂商性质
福州市所在地
IB IL 24 DO8/HD-PAC菲尼克斯输入输出模块
面议信号变送器MINI MCR-2-F-UI-PT-C菲尼克斯
面议输入输出模块IB IL 24 DO 4-XC-PAC菲尼克斯
面议MINI MCR-2-UI-I-OLP-PT-C信号变送器
面议菲尼克斯信号变送器MINI MCR-2-POT-UI-C
面议IB IL 24 DI 16-NPN-PAC输入输出模块
面议菲尼克斯IB IL 24 DI 4-XC-PAC输入输出模块
面议信号变送器MACX MCR-EX-SL-RPSS-2I-2I
面议输入输出模块IB IL 24 DO 32/HD-NPN-PAC
面议IB IL 24 DI 4-XC-PAC菲尼克斯输入输出模块
面议信号变送器MACX MCR-SL-RPSS-2I-2I-SP
面议菲尼克斯输入输出模块IB IL 24 PSDI 16-PAC
面议浪涌保护器VAL-MS230/3+1/FM菲尼克斯FLT-SEC-H-T1-1C-264/25-FM用于直流电源的电涌保护器 VALVETRAB-SEC DC是用于线性 直流电源的电涌保护器。
FLT-SEC-P-T1-3C-440/35-FM
FLT-SEC-H-T1-3C-440/25-FM
VAL-SEC-T2-3C-440-FM
VAL-MS750/30/3+0-FM
VAL-SEC-T2-1S-175-FM
PLT-SEC-T3-120-FM-PT
VAL-SEC-T2-2+0-48DC-FM
VAL-SEC-T2-2+F-48DC-FM
PLT-SEC-T3-24-FM-PT
VAL-SEC-T2-2+0-48DC-FM
VAL-SEC-T2-2+F-48DC-FM
PLT-SEC-T3-60-FM-PT
VAL-SEC-T2-2+0-120DC-FM
VAL-SEC-T2-2+F-120DC-FM
PLT-SEC-T3-120-FM-PT
VAL-SEC-T2-2+0-220DC-FM
VAL-SEC-T2-2+F-220DC-FM
PLT-SEC-T3-230-FM-PT
导线横截面要求参见相邻表格。 – 必须与主回路接地导轨(S6)连接(如图所示)。 – S6必须使用横截面16 mm²以上的电缆。如果应用中要求该 连接(S6)等于与保护导线的连接(SPE),则SPE应使用横 截面35 mm²以上的电缆。 – 如果电缆横截面积大于35 mm²,电涌保护器的连接电缆 (SL)必须受到接地故障和短路保护。建议:SL应使用温度 稳定性高的电缆,例如XLPE/EPR绝缘电缆。 – 连接电缆应尽可能短,在敷设时应注意避免形成回路,并使 电缆弯曲半径尽可能增大。
– 无续流放电间隙和抗电涌熔断器的组 合 – 内置过流保护,无需配备后备保护熔 断器 – 无漏流 – 440 V型号能够满足IT系统的TOV需求 – 创新的推拉式弹簧锁扣,便于插拔 – 低电压保护水平:264 V型号为 1.5 kV,440 V型号为2.5 kV – 可视状态指示窗口 – 带遥信触点 – 可通过CHECKMASTER 2检测
– 双接线端子,可安全方便地进行等电 位连接 – 螺纹轴及升高的拱形顶确保工作安全 – 采用凸起式的连接口增加爬电距离 – 可视状态指示窗口 – 可视化显示,方便现场直接检查产品 状态 – 插拔式的远程遥信报警触点 – 紧凑型设计,节省安装空间
浪涌保护器VAL-MS230/3+1/FM菲尼克斯FLT-SEC-H-T1-1C-264/25-FM用于直流电源的电涌保护器 VALVETRAB-SEC DC是用于线性 直流电源的电涌保护器。
VAL-SEC-T2-2+F-48DC-FM
VAL-SEC-T2-2+F-220DC-FM
VAL-SEC-T2-2+F-120DC-FM
VAL-SEC-T2-2+F-380DC-FM
VAL-SEC-T2-48DC-P
VAL-SEC-T2-220DC-P
VAL-SEC-T2-120DC-P
VAL-SEC-T2-380DC-P
VAL-SEC-T2-GDT-400DC-P
VAL-SEC-T2-GDT-800DC-P
VAL-SEC-T2-2+0-48DC-FM
VAL-SEC-T2-2+0-220DC-FM
VAL-SEC-T2-2+0-120DC-FM
VAL-SEC-T2-2+0-380DC-FM
VAL-SEC-T2-48DC-P
VAL-SEC-T2-220DC-P
VAL-SEC-T2-120DC-P
VAL-SEC-T2-380DC-P
VAL-SEC-T2-GDT-400DC-P
VAL-SEC-T2-GDT-800DC-P
VAL-MB-T2 1500DC-PV/2+V-FM
VAL-MB-T2 1500DC-PV/2+V
VAL-MS1500DC-PV/2+V-FM
VAL-MS1500DC-PV/2+V
VAL-MS1000DC-PV/2+V-FM
VAL-MS-CN1000DC-PV/4+V-FM
VAL-MS1000DC-PV/2+V
VAL-MS600DC-PV/2+V-FM
VAL-MS600DC-PV/2+V
VAL-MS1500DC-PV-ST
VAL-MS1000DC-PV-ST
VAL-MS600DC-PV-ST
VAL-MS4+V/BE/FM
VAL-CP-MCB-3S-350/40/FM
VAL-CP-MCB-1S-350/40/FM
VAL-CP-350-ST-GY
VAL-CP-350-ST-GY
VAL-CP-N/PE-350-ST-GY 2
VAL-CP-MOSO60-3S-FM
VAL-CP-350-ST-GY
VAL-CP-N/PE-350-ST-GY
PLT-SEC-T3-3S-230-FM
并可显示过载导致的保护性 元件通断,用户可以持续了解电涌保护 器状态,并及时维护及更换。 遥信 遥信模块可选,可自行决定是否需 要以及何时需要此模块。可轻松将遥信 模块与已安装的电涌保护器并列安装, 实现群组监控。如果在过载情况下保护 性元件断开,则断开的设备关闭监控通 道,并触发群组遥信功能。在现场通过 状态指示灯检测过载设备,该操作无需 辅助电源,为纯机械操作。 应用广泛 TERMITRAB complete应用广泛, 适合各种行业。配电柜通常要求高密度 安装,该产品采用超薄设计,最小宽度 仅为3.5 mm,是过程控制系统的理想选 择。该产品在一米的宽度内最多可保护 572个信号,系统更紧凑。通过多种认 证,适用于陆上和海上系统,如石化或 风电系统。可定制的 TERMITRAB complete产品提供种类繁 多的功能,为各种应用提供非常合适的 解决方案, 可靠保护现场至控制器之间 的信号免受电涌电压影响。 快速接线 TERMITRAB complete可采用传统 的螺钉连接技术和创新的直插式连接技 术,从而确保了在控制柜中的快速安 装。此外,直插式连接技术实现了电涌 保护器的机械布线,是一种面向未来的 智能自动化解决方案。