其他品牌 品牌
代理商厂商性质
广州市所在地
COC-THC 违禁品多联卡检测试纸
广州健仑生物科技有限公司
独立包装:BZO-BAR-COC--THC -MET--OPI-OXY-MDMA-PCP- AMP-XTC-MTD 或联检
COCAINE (COC)
Benzoylecgonine conc. (ng/mL) | n per site | Site A | Site B | Site C | |||
- | + | - | + | - | + | ||
0 | 15 | 14* | 0 | 15 | 0 | 15 | 0 |
150 | 15 | 14 | 1 | 15 | 0 | 14 | 1 |
225 | 15 | 4 | 11 | 5 | 10 | 8 | 7 |
375 | 15 | 0 | 15 | 0 | 15 | 0 | 15 |
450 | 15 | 0 | 15 | 0 | 15 | 1 | 14 |
COC-THC 违禁品多联卡检测试纸
COCAINE | Ng/ml |
Benzoylecgonine | 300 |
Cocaine HCl | 780 |
Cocaethylene | 12,500 |
Ecgonine HCl | 32,000 |
MARIJUANA (THC) |
|
11-nor-D9 -THC-9 COOH | 50 |
Cannabinol | 20,000 |
11-nor-D8-THC-9 COOH | 30 |
D8 -THC | 15,000 |
D9 -THC | 15,000 |
Fifteen (15) urine samples of normal, high, and low specific gravity ranges (1.000-1.037) were spiked with drugs at 50% below and 50% above cut-off levels respectively. The One Step Drug Screen Test Card was tested in duplicate using fifteen drug-free urine and spiked urine samples. The results demonstrate that varying ranges of urinary specific gravity does not affect the test results.
Effect of the Urinary pH
The pH of an aliquoted negative urine pool was adjusted to a pH range of 5 to 9 in 1 pH unit increments and spiked with drugs at 50% below and 50% above cut-off levels. The spiked, pH-adjusted urine was tested with One Step Drug Screen Test Card. The results demonstrate that varying ranges of pH does not interfere with the performance of the test.
A study was conducted to determine the cross-reactivity of the test with compounds in either drug-free urine or drug positive urine containing Cocaine, Barbiturates, Benzodiazepine, Amphetamine, Methamphetamine, Marijuana, Methadone, Opiate, Phencyclidine or Tricyclic Antidepressant. The following compounds show no cross-reactivity when tested with One Step Drug Screen Test Card at a concentration of 100 mg/mL.
【检验方法】
在进行检测前必须先完整阅读使用说明书,使用前将本品和尿样恢复至室温(20℃~30℃)。
【参考值(参考范围)】
本品zui低检出量指标参照美国药物滥用和精神健康服务管理局(SAMHSA)确定的阳性检测临界浓度的标准进行制定。能检测出尼古丁含量不低于300ng/mL的样本。
【检验结果的解释】
阳性(+):仅在控制区(C)出现一条紫红色条带,在检测区(T)无紫红色条带出现。阳性结果表明尿液中的尼古丁浓度在阈值(300ng/mL)以上。
阴性(-):出现两条紫红色条带。一条位于检测区(T),另一条位于控制区(C)。阴性结果表明尿液中的尼古丁浓度在阈值(300ng/mL)以下。
无效:控制区(C)未出现紫红色条带。表明操作不当或试剂盒已失效。在此情况下,应再次仔细阅读说明书,并用新的试剂盒重新测试。如果问题仍然存在,应立即停止使用此批号产品,并与当地供应商。
注意:检测区(T)紫红色条带可呈现颜色深浅的现象。但是,在规定的观察时间内,不论该色带颜色深浅,即使只有非常弱的色带也应判定为阴性结果。
美国NOVABIOS多联检测杯简介:
产品名称 | 规格 | 检测违禁品类型 |
违禁品十联检测杯 | 25T/盒 | MET.AMP.MTD.THC.BAR.TCA.COC.BZO.PCP.OPI |
违禁品十三联检测杯 | 25T/盒 | AMP.BAR.BZO.COC.MET.MOR.MTD.PCP.PPX.TCA.THC.XTC.WADU |
违禁品十二联检测杯 | 25T/盒 | BZO.BAR.COC.THC.MET.OPI.OXY.MDMA.PCP.AMP.BUP.MTD
|
美国NOVABIOS单卡产品简介:
产品名称 | 英文缩写 | 检测阀值 |
吗啡检测试剂盒 | MOP(OPI) | 300ng/ml |
mamp检测试剂盒 | MAMP(MET) | 1000ng/ml |
K检测试剂盒 | KET | 1000ng/ml |
Ecstasy检测试剂盒 | MDMA | 500ng/ml |
cocaine检测试剂盒 | COC | 300ng/ml |
hemp检测试剂盒 | THC | 50ng/ml |
Amphetamine检测试剂盒 | AMP | 1000ng/ml |
Benzene two nitrogen Zhuo检测试剂盒 | BZO | 300ng/ml |
巴比妥检测试剂盒 | BAR | 300ng/ml |
Methadone检测试剂盒 | MTD | 300ng/ml |
COC-THC 违禁品多联卡检测试纸
尿液试纸、唾液试纸、尼古丁检测卡、烟碱检测卡、违违禁品三联检测卡、违禁品五联检测卡、违禁品十联检测卡、药筛试剂、违禁品滥用检测试纸、违禁品快速检测试剂盒
更多产品说明可通过下方的进行了解
添加扫一扫二维码:
【公司名称】 广州健仑生物科技有限公司
【 市场部 】 杨永汉
【】
【腾讯 】
【公司地址】 广州市清华科技园健新基地番禺石楼镇健启路63号二期2幢101-103室
Although many research results have accelerated the amplification of PCR systems, they have not been developed yet
A new thermal cycling process was achieved that was significantly faster than existing DNA denaturation and annealing rates. Over the years
, Scientists have been committed to research and development with low consumption, easy operation, small size and other advantages
Ultra-fast PCR instrument. Its superb speed will have a big impact on real-time diagnostics.
Recently, Dr. Luke Lee, a bioengineering professor at the University of California, Berkeley, and his team
Developed a speeding photoelectric photoelectric PCR technology - can significantly speed up DNA denaturation in PCR reaction, back
Fire speed. Design Principle: When exposed to light, free electrons oscillate and generate heat
. Once the light is off, the electrons stop shaking and no longer generate heat.
Based on the above physics, in order to speed up the temperature cycling, the researchers used a
With bacteria absorb light energy, bacteria in the spectrum analysis of the material - gold, choose thick
About 120nm gold foil wrapped microfluidic chip, which can be placed mixed with PCR
Reaction solution and DNA sample solution tube.
The researchers selected the peak wavelength of about 450nm LED lamp, light activated gold film surface
Of electrons to reach 13 ° C per second to heat the DNA solution. Similarly, when cooled, the temperature is
6.6 ℃ per second rate of decline.
The temperature was raised to 95 ° C at 55 ° C and 30 cycles of PCR were allowed to be controlled within 5 minutes
It takes about an hour for the PCR instrument to complete.
To prove the practical value of their newly developed system, researchers use photons
PCR instrument to amplify DNA samples, the result is positive bacteria. Photoelectric PCR instrument speed, sensitivity of bacteria
,low cost. Researchers are also developing ultra-speed gene diagnostic chip. This technology can mention
For immediate results, the application of broad prospects.
About 252 million years ago, about 90% of the species on Earth suddenly disappeared, which is known as five
Sub-species of the largest extinction. The reasons for the extinction of this species so far are unclear
.
The United States and Chinese scientists jointly published the Proceedings of the National Academy of Sciences in March 2014
(Proceedings of the National Academy of Sciences, PNAS)
One article may provide clues as to why 252 million years ago the species was massively extinct.
Recent research shows that the cause of mass extinction is not due to asteroids, volcanoes or raging
Coal fire, but due to a methanogenic archaea: Methanosarcina
(Methanosarcina). Methanosarcina in the ocean suddenly a large number of explosive
Colonization, resulting in a large amount of methane, the chemical composition of the climate and the oceans drastic changes, resulting in
Species extinct. The reason why the marine methane sarcinaceae suddenly explosive mass reproduction,
May be due to large-scale volcanic activity, the growth of this bacteria needed to bring the nickel element
Ocean, resulting in the multiplication of bacteria.