AMC-1 Anion Microconcentrator Column
面议AC10 Anion Concentrator Column
面议AC15 Anion Concentrator Column
面议TBC-1 Trace Borate Concentrator Column
面议TCC-2 Trace Cation Concentrator Column
面议TCC-LP1 Low-Pressure Trace Cation Concentrator Col
面议TCC-ULP1 Ultralow Pressure Trace Cation Concentrat
面议TCC-XLP1 Extremely Low Pressure Trace Cation Conce
面议MCC-100 Monolith Cation Concentrator Column
面议MCC-200 Monolith Cation Concentrator Column
面议TMC-1 Trace Metal Concentrator Column
面议MetPac CC-1 Chelating Column
面议Oligosaccharides released from therapeutic glycoproteins can differ in size, charge, branching, and linkage. Oligosaccharides with these features can be resolved using the CarboPac® PA100. It provides the flexibility to separate oligosaccharides into broad classes depending upon the degree of sialylation, while maintaining the resolution needed for routine analysis based on linkage isomerism. Coupled with pulsed amperometric detection, the PA100 supports detection at low-picomole levels.
Separation of closely related oligosaccharides, even isomers, at picomole levels
Separation of neutral and charged oligosaccharides in the same run
No sample derivatization required for detection
The CarboPac PA100 column is a high-resolution, strong anion-exchange column for enhanced chromatography of oligosaccharides.
The Carbohydrate Membrane Desalter can be used on-line prior to fraction collection.
CarboPac PA100 Column for Oligosaccharide Analysis Specifications | |
---|---|
Dimensions | CarboPac PA100 Analytical Column: 4 × 250 mm CarboPac PA100 Guard Column: 4 × 50 mm CarboPac PA100 Microbore Column: 2 × 250 mm CarboPac PA100 Microbore Guard Column: 2 × 50 mm CarboPac PA100 Semipreparative Column: 9 × 250 mm CarboPac PA100 Semipreparative Column: 22 × 250 mm |
Maximum operating pressure | 4000 psi (27.9 MPa) |
Temperature range | 4–60 °C Recommended operating temperature: ambient |
Typical operating conditions | 2400 psi at 1.0 mL/min (analytical and guard columns) Recommended flow rate: 1.0 mL/min |
phase compatibility | pH 0–14; * compatible with common organic solvents. Ionic form eluents: sodium acetate and sodium hydroxide only. |
Resin composition | 8.5-µm-diameter ethylvinylbenzene/divinylbenzene substrate (55% cross-linking) agglomerated with 275-nm MicroBead™ quaternary amine functionalized latex (6% cross-linked). |
Anion-exchange capacity | Approximay 90 µeq/column (4 × 250 mm analytical column) |