E+H/德国恩德斯豪斯 品牌
代理商厂商性质
福州市所在地
CAS51D-AAA1B4+IB德国E+H传感器
面议CLS16-4G2A1U德国E+H电导率电极
面议CPM253-MR0005德国E+H变送器CPM253-MS0005
面议CLD134-SCS158AA1德国E+H电导率仪
面议德国E+H一体式电导率仪CLD134-WAA558AB1
面议CUS52D-AA1BA3浊度分析仪CUS52D-AA1AB3
面议CPM253-MR8125德国E+H分析仪变送器
面议CLS50-G1A2德国E+H电导率电极CLS21-L3B4D
面议CPF81-NN12C3德国E+H PH电极CPF81-LH11D3
面议CPM223-PS0005分析变送器CPM253-PR0005
面议CLD134-PAA558AB1德国E+H一体化电导率仪
面议CUS51D-AAC1B3德国E+H浊度仪CUS51D-AAC1A3
面议CPM223-PS0005德国E+H分析仪变送器CPM223-MS0005使用pH 单杆测量单元时
CPM223-MR8005 CPM223-MS8005 CPM223-PR1005 CPM223-PS1005 CPM253-MR1005 CPM253-MS1005
CPM253-PR8005 CPM253-PS8005 CLM253-CD0005 CLM253-CS0005 CLM253-ID0005 CLM253-IS0005
CPM253-MS0010 CPM253-PR0010 CPM253-PS0010 CPM223-IS0005 CPM223-MR0005 CPM223-MS0005
CPM223-PR0005 CPM223-PS0005 CPM223-IS0105 CPM223-MR0105 CPM223-MS0105 CPM223-PR0105
CPM223-PS0105 CPM223-IS0010 CPM223-MR0010 CPM223-MS0010 CPM223-PR0010 CPM223-PS0010
COM223-DS0105 COM223-DX0105 COM223-WS0105 COM223-WX0105 COM223-DS1105 COM223-DX1105
COM223-WS1105 COM223-WX1105 COM223-DS1005 COM223-DX1005 COM223-WS1005 COM223-WX1005
误识别为测量信号的一部分,导致测量误差。在污水中测量时,钾离子和氨离子的化学属性相
似,但会导致更高的测量值。高浓度氯离子会导致硝氮测量值过高。为了减小此类相互干扰导致
的测量误差,可以测量钾或氯干扰离子浓度,并使用附加电极对此进行补偿。
测量系统完整的测量系统包括:
• CAS40D 传感器
– 离子选择性电极,用于氨氮、硝氮、钾离子或氯离子测量
– 温度传感器CTS1
可选:
• 安装支座,例如 CYH112
• 防护罩- 户外安装变送器时必须使用防护罩!
• 压缩空气供给单元(现场无法提供压缩空气时)
浓度波动(非绝对值)是决定性因素
2) 建议:当钾离子浓度超过40 mg/l,且在± 20 mg/l 范围内波动时,使用补偿电极。未出现波动值时可以
加上偏置量。
3) 浓度波动(非绝对值)是决定性因素
4) 建议:当氯离子浓度超过500 mg/l,且在± 100 mg/l 范围内波动时,使用补偿电极。未出现波动值时
可以加上偏置量。
应用
二氧化氯用于水消毒时,应根据操作条件要求,严格控
制剂量。浓度过低,会影响消毒效果;浓度过高,会产
生腐蚀效应、破坏口感或刺激皮肤。
CCS240 和CCS241 二氧化氯传感器可用于下列场合中的
二氧化氯测量:
• 饮用水处理
• 池水处理
• 工业水处理
优势
• 与CCA250 流通式安装支架配套使用时,流量高于
30 l/h 时,测量不受流体流速的影响
• 无需零点标定。也无需像开放式二氧化氯传感器那样
安装复杂的活性碳过滤器
• 测量值不受介质电导率波动的影响
• CCS240 传感器需要约10...30 min 的极化时间,
CCS241 传感器需要45...90 min 的极化时间,
即可以直接用于测量
• 预标定的覆膜头易于进行覆膜更换
• 恒定操作条件下的重新标定间隔时间约为1...4 个月
功能与系统设计
功能CCS240 和CCS241 传感器用于二氧化氯测量。覆膜法CCS240 和CCS241 传感器由阴极和阳极组
成,阴极为工作电极,阳极为反电极。阴极和阳极浸入在电解液中,通过覆膜与介质隔离。覆膜
可以防止电解液泄漏或污染物渗入。
基于DPD 法( 光度法) 测量二氧化氯浓度,标定测量系统。因此,需要使用显色试剂测量原理的
光度计。测定值即为输入至变送器中的标定值。
测量原理基于覆膜法测量原理测量二氧化氯浓度。介质中的二氧化氯(ClO2) 扩散通过传感器覆膜,在金阴
极上还原成氯离子(Cl-) ;在银阳极上,银被氧化成氯化银。金阴极释放电子,银阳极接收电子,
形成电流回路,回路电流与介质中的二氧化氯浓度成比例关系。适用于宽pH 值和温度测量范围。
变送器将电流信号转换成浓度值( 单位:mg/l)。
测量系统完整的测量系统包括:
• 二氧化氯传感器
• 专用测量电缆
• 流通式安装支架
• 参比测量仪表,基于DPD 法测量二氧化氯
CCA250 流通式安装支架设计用于现场安装传感器。除了可以安装余氯或二氧化氯传感器,还可以
安装pH 电极和ORP 电极。使用针阀调节流量,将流量保持在30...120 l/h (7.92...31.7 US.gal/h) 之
间。
安装传感器时,请注意以下几点:
• 流量不得低于30 l/h
流量低于30 l/h或流体停滞时,感应式接近开关可以检测出此状况,触发报警
信号,并锁定加料泵,停止加料。
• 介质需要回流至缓冲罐、管路或类似容器中时,请确保由此导致的传感器背压维持恒定,且不
会超过1 bar (14.5 psi)。
• 必须避免传感器上出现负压,例如:泵的反吸导致介质回流。
详细安装指南请参考流通式安装支架的《操作手册》。
卫生型测量系统,用于在食品、饮料、制药行业
和生物技术领域中进行电导率和浓度测量
应用
电感式电导率测量系统特别适用于食品、饮料、制药行业和生物技术领域中的卫生
型应用。测量系统通过卫生型认证,采用食品安全的天然PEEK 材质和无接头无缝
隙结构设计,满足上述行业中的严格卫生要求。提供一体式和分体式系统供用户选
择。 Smartec CLD134 特别适用于:
• 管路系统中产品/水和产品/产品混合液的相分离
• 回流管道中的原位清洗(CIP)控制
• CIP 清洗液浓度控制
• 管路系统、瓶装厂、质量监控的产品监测
• 泄露监测
可以在下列行业中使用:
• 乳品
• 酿酒
• 饮料(水、果汁、软饮料)
• 制药和生物技术
优势
•卫生型设计,无二次污染风险
• 通过卫生行业所需的所有认证
• 不锈钢变送器外壳满足卫生要求
• 采用整体密封的无缝结构设计,使用寿命长
• 响应迅速,温度响应时间t90 小于26 s,确保安全高效的相分离
• 多种操作方式可选,使用灵活:
– 键盘– 安装有调试工具的个人计算机(基于FDT/DTM 技术)
• 使用远程参数设定开关(量程切换)实现标准型系统的功能升级
功能与系统设计
测量原理电感式电导率测量原理示意图
发生器(1)在初级线圈(2)处生成交变电磁场,导致介质(3)中出现感应电流。电流强度与电导率相
CPM223-PS0005德国E+H分析仪变送器CPM223-MS0005使用pH 单杆测量单元时
COM223-DS8005 COM223-DX8005 COM223-WS8005 COM223-WX8005 CCM253-EK0005 CCM253-EP0005
CCM253-ES0005 CCM253-EK0105 CCM253-EP0105 CCM253-ES0105 CCM253-EK1005 CCM253-EP1005
CCM253-ES1005 CCM253-EK8005 CCM253-EP8005 CCM253-ES8005 CCM253-EK1105 CCM253-EP1105
CCM223-ES0005 CCM223-EK0105 CCM223-EP0105 CCM223-ES0105 CCM223-EK1005 CCM223-EP1005
CCM223-EK0005 CCM223-EP0005 CCM223-ES1005 CCM223-EP8005 CCM223-ES8005 CCM223-EK1105
CLM223-CD1005 CLM223-CS1005 CLM223-ID1005 CLM223-IS1005 CLM223-CD0110 CLM223-CS0110
CLM223-ID0110 CLM223-IS0110 CLM223-CD8005 CLM223-CS8005 CLM223-ID8005 CLM223-IS8005
COM253-DS0005 COM253-DX0005 COM253-WS0005 COM253-WX0005 COM253-DS0105 COM253-DX0105
CLM253-CD0105 CLM253-CS0105 CLM253-ID0105 CLM253-IS0105 CLM253-CD1005 CLM253-CS1005
CLM253-ID1005 CLM253-IS1005 CLM253-CD0110 CLM253-CS0110 CLM253-ID0110 CLM253-IS0110
CPM253-IS0005 CPM253-MR0005 CPM253-MS0005 CPM253-PR0005 CPM253-PS0005 CPM253-IS0105
• 必须由经授权的合格专业技术人员( 例如:电工) 进行设备的安装、电气连接、调
试和维护;必须严格遵守《简明操作指南》、应用规范、法律法规和证书( 取决于
应用条件) 中的各项规定。
• 技术人员必须阅读《简明操作指南》,理解并遵守其中的各项规定。如仍有任何疑
问,必须阅读《操作手册》。《操作手册》提供设备/ 测量系统的详细信息。
• 仅允许进行《操作手册》中明确允许的设备改动或维修。
• 故障无法修复时,设备必须停用,防止误调试。
• 不得操作已损坏的设备,并对已损坏的设备进行标识。
1.3 操作安全和过程安全
• 必须采取交替监控措施确保设备在设置、测试和维护过程中始终满足操作安全和过
程安全的要求。
• 设备的制造和测试符合*、严格的安全要求。出厂时,符合技术安全要
求。遵守适用法规和欧洲标准的要求。
• 请注意铭牌上的技术参数。
• 在具有整体安全性要求的应用场合中使用设备时,必须遵守单独成册的《功
能安全手册》的要求。
仅允许在常压状态下拆卸仪表!
1.4 返回
返回设备的详细信息请参考《操作手册》。
模拟量产品标识
1.5 安全图标
2 产品标识
测量设备的标识信息如下:
• 铭牌参数
• 扩展订货号,标识供货清单上的设备特征
中输入铭牌上的序列号:
显示测量设备的所有信息
包装中的技术资料文档信息的查询方式如下:
在中输入铭牌上的序列号。
图标说明
“ 警告” 图标表示:操作或步骤执行错误将导致人员受伤、安全事故或设备损坏。
“ 小心” 图标表示:操作或步骤执行错误可能导致人员受伤或设备功能错误。
! 注意!
“ 注意” 图标表示:操作或步骤执行错误可能会间接影响操作,或导致设备发生意外响应。
安装Cerabar M 4...20 mA 模拟量
3 安装
# 警告!
禁止将密封圈压紧在过程隔离膜片上,否则会影响测量结果。
3.1 安装位置
! 注意!
• Cerabar M 的安装位置可能导致测量值偏差。例如:在空容器中测量时,显示的测量
值并非为0。可以校正零点迁移(“ 操作单元的功能” ( ä 14))。
• PMP55:请参考章节3.3 “ 带隔膜密封系统的仪表的安装指南(PMP55)” ( ä 7)。
• Endress+Hauser 提供仪表的柱式或壁式安装支架( 参考《操作手册》BA00385P)。
3.2 不带隔膜密封系统的仪表的安装指南(PMP51、PMC51)
! 注意!
• 始终保持压力补偿口和GORE-TEX? 过滤口(1) 洁净、无污染。
• 遵守压力表规范(DIN EN 837-2) 安装不带隔膜密封系统的Cerabar M 变送器。
建议使用截止阀和冷凝管。安装位置取决于测量应用条件。
• 请勿使用坚硬或尖锐物品清洁或接触过程隔离膜片。
• 热的Cerabar M 在清洗过程中会被冷却( 例如:使用冷水清洗),短时间内将形成真
空。此时,水可以通过压力补偿口(1) 渗入传感器内。在此情形下安装Cerabar M
时,应确保压力补偿口(1) 朝下放置。
模拟量安装
3.2.1 气体压力测量
• 将带截止阀的Cerabar M 安装在测量点之上,确保冷凝物能回流至过程中。
3.2.2 蒸汽压力测量
• 将带冷凝管的Cerabar M 安装在测量点之上。
• 调试前,冷凝管中注满填充液。
冷凝管能使温度降低至接近环境温度。
3.2.3 液体压力测量
• 将带截止阀的Cerabar M 安装在测量点之下,或与测量点等高度安装。
3.2.4 液位测量
• 始终将Cerabar M 安装在低测量点之下。
• 请__刜__?_@勿在加料区中或罐体内会受到搅拌器产生的压力脉冲信号影响的位置处安装仪
表。
• 请勿在泵的抽吸区中安装仪表。
• 将仪表安装在截止阀的下游位置处,便于进行仪表标定和功能测试。
3.3 带隔膜密封系统的仪表的安装指南(PMP55)
! 注意!
• 带隔膜密封系统的Cerabar M 可以采用螺纹、法兰或夹持式安装,取决于隔膜密封系
统的类型。
• 隔膜密封系统和压力变送器共同组成密闭的已标定系统,通过隔膜密封系统和测量
系统中压力变送器的开口充注填充液。开口已密封,不得打开。
• 请勿使用坚硬或尖锐物品清洁或接触过程隔离膜片。
• 安装前,请勿拆除过程隔离膜片上的防护盖。
• 使用安装支架安装时,必须充分消除毛细管上的应力,防止毛细管过度弯曲
( 弯曲半径:100 mm (3.94 in))。
• 请注意:毛细管中液柱的静压力可能会导致零点迁移。可以进行零点迁移校正。
• 请注意隔膜密封系统填充液的应用限定值,详细信息请参考Cerabar M 的《技术资
料》TI00436P 中的“ 隔膜密封系统的设计指南”。